Power Window Control System: Inspection
- INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSY
- Check the continuity between each terminal of the connector.
NOTE: Whether the operation is good or bad can be judged by the basic function check, because the continuity cannot be checked by UP/DOWN operation of the driver side switch.Standard (Window unlock):
POWER WINDOW UNLOCK POSITION TERMINALSwitch Position Passenger Side Terminals No. Rear RH Terminals No. Rear LH Terminals No. UP 6 - 13(1)(6 - 18(2)), 1 - 15 6 - 18(1)(6 - 10(2)), 1 - 16 6 - 12, 1 - 10(1)(1 - 13(2)) OFF 1 - 13(1)(1 - 18(2)), 1 - 15 1 - 18(1)(1 - 10(2)), 1 - 16 6 - 12, 1 - 10(1)(1 - 12(2)) DOWN 6 - 15, 1 - 13(1)(1 - 18(2)) 6 - 16, 1 - 18(1)(1 - 10(2)) 6 - 10(1)(6 - 13(2)), 1 - 12 (1) w/ Jam protection (2) w/o Jam protection Standard (Window lock):
POWER WINDOW LOCK POSITION TERMINALSwitch Position Passenger Side Terminals No. Rear RH Terminals No. Rear LH Terminals No. UP 6 - 13(1)(6 - 18(2)) 6 - 18(1)(6 - 10(2)) 6 - 12 OFF 13 - 15(1)(18 - 15(2)) 16 - 18(1)(1 - 10(2)) 10 - 12 DOWN 6 - 15 6 - 16 6 - 10(1)(6 - 13(2)) (1) w/ Jam protection (2) w/o Jam protection If the continuity is not as specified, replace the switch.
- INSPECT POWER WINDOW REGULATOR SWITCH ASSY
- Check the continuity between each terminal of the connector when operating the switch.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard:
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the continuity is not as specified, replace the switch.
- Check the continuity between each terminal of the connector when operating the switch.
- INSPECT POWER WINDOW REGULATOR MOTOR ASSY LH CAUTION:
- Be sure not to apply battery voltage to terminals 2, 3 and 6 of the power window regulator motor assy LH connector, because it might damage the pulse sensor and the limit switch.
- Be sure to reset the power window regulator motor assembly (initial position setting of the limit switch) when the power window regulator motor assy LH is installed to the regulator (See step 24 under OVERHAUL ).
- Inspect operation of the front LH power window regulator motor assembly.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- When adding battery voltage to each connector terminal, check that the motor operates smoothly.
Standard:
- Check operation of the PTC inside the power window regulator motor.NOTE: Work must be performed with the power window regulator and door glass installed to the vehicle.
- Set the DC 400 A probe to terminal 4 or 5 of the wire harness.NOTE: Match the arrow mark of the probe with the current direction.
- Set the door glass at the fully closed position.
- When approximately 60 seconds have passed after fully closing the door glass, check how long the current takes to change from approximately 16 - 34 A to less than 1 A when pulling the power regulator switch UP furthermore (at initial time).
Standard: Approximately 4 - 90 seconds
- When approximately 60 seconds have passed after the cut-off check, check that the door glass goes down when the power regulator switch is pressed DOWN.
- Set the DC 400 A probe to terminal 4 or 5 of the wire harness.
- INSPECT POWER WINDOW REGULATOR MOTOR ASSY RH
- Inspect operation of the front RH power window regulator motor assembly.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- When adding battery voltage to each connector terminal, check that the motor operates smoothly.
Standard:
- Check operation of the PTC inside the power window regulator motor.NOTE: Work must be performed with the power window regulator and door glass installed to the vehicle.
- Set the DC 400 A probe to terminal 4 or 5 of the wire harness.NOTE: Match the arrow mark of the probe with the current direction.
- Set the door glass at the fully closed position.
- When approximately 60 seconds have passed after fully closing the door glass, check how long the current takes to change from approximately 16 - 34 A to less than 1 A when pulling the power regulator switch UP furthermore (at initial time).
Standard: Approximately 4 - 90 seconds
- When approximately 60 seconds have passed after the cut-off check, check that the door glass goes down when the power regulator switch is pressed DOWN.
- Set the DC 400 A probe to terminal 4 or 5 of the wire harness.
- Inspect operation of the front RH power window regulator motor assembly.
- INSPECT POWER WINDOW REGULATOR MOTOR ASSY LH
- Inspect operation of the rear LH power window regulator motor assembly.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- When adding battery voltage to each connector terminal, check that the motor operates smoothly.
Standard:
- Check operation of the PTC inside the power window regulator motor.NOTE: Work must be performed with the power window regulator and door glass installed to the vehicle.
- Set the DC 400 A probe terminal 4 or 5 of the wire harness.NOTE: Match the arrow mark of the probe with the current direction.
- Set the door glass at the fully closed position.
- When approximately 60 seconds have passed after fully closing the door glass, check how long the current takes to change from approximately 16 - 34 A to less than 1 A when pulling the power regulator switch UP furthermore (at initial time).
Standard: Approximately 4 - 90 seconds
- When approximately 60 seconds have passed after the cut-off check, check that the door glass goes down when the power regulator switch is pressed DOWN.
- Set the DC 400 A probe terminal 4 or 5 of the wire harness.
- Inspect operation of the rear LH power window regulator motor assembly.
- INSPECT POWER WINDOW REGULATOR MOTOR ASSY RH
- Inspect operation of the rear RH power window regulator motor assembly.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- When adding battery voltage to each connector terminal, check that the motor operates smoothly.
Standard:
- Check operation of the PTC inside the power window regulator motor.NOTE: Work must be performed with the power window regulator and door glass installed to the vehicle.
- Set the DC 400 A probe to terminal 4 or 5 of the wire harness.NOTE: Match the arrow mark of the probe with the current direction.
- Set the door glass at the fully closed position.
- When approximately 60 seconds have passed after fully closing the door glass, check how long the current takes to change from approximately 16 - 34 A to less than 1 A when pulling the power regulator switch UP furthermore (at initial time).
Standard: Approximately 4 - 90 seconds
- When approximately 60 seconds have passed after the cut-off check, check that the door glass goes down when the power regulator switch is pressed DOWN.
- Set the DC 400 A probe to terminal 4 or 5 of the wire harness.
- Inspect operation of the rear RH power window regulator motor assembly.
- INSPECT POWER WINDOW RELAY ASSY
- Inspect the power window relay continuity.
Standard:
If the continuity is not as specified, replace the relay.
- Inspect the power window relay continuity.