Power Window Control System: Inspection
- POWER WINDOW SYSTEM CIRCUIT
- INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSY
- Inspect the master switch continuity.
Driver's switch (Window unlock and lock)
Standard:
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Front passenger's switch (Window unlock)
Standard:
Front passenger's switch (Window lock)
Standard:
FRONT PASSENGER Switch TableSwitch position Symbols (Terminal No.) Specified condition UP B (6) <--> B (7) <--> RLU (18) Continuity OFF PD (15) <--> PU (18) Continuity DOWN B (6) <--> B (7) <--> PD (15) Continuity Rear left switch (Window unlock)
Standard:
Rear left switch (Window lock)
Standard:
REAR LEFT SWITCHSwitch position Symbols (Terminal No.) Specified condition UP B (6) <--> B (7) <--> RLU (12) Continuity OFF RLU (12)<-->RLD (13) Continuity DOWN B (6) <--> B (7) <--> RLD (13) Continuity Rear right switch (Window unlock)
Standard:
Rear right switch (Window lock)
Standard:
REAR RIGHT SWITCHSwitch position Symbols (Terminal No.) Specified condition UP B (6) <--> B (7) <--> RRU (10) Continuity OFF RRU (10) <--> RRD (16) Continuity DOWN B (6) <--> B (7) <--> RRD (16) Continuity If the result is not as specified, replace the master switch.
- Inspect the master switch illumination.
Standard:
MASTER SWITCH ILLUMINATIONMeasuring condition Specified condition Battery positive (+) Terminal - 6 Switch illumination lights up Battery negative (-) Terminal -3 Switch illumination lights up If the result is not as specified, replace the master switch.
- Inspect the master switch continuity.
- INSPECT POWER WINDOW REGULATOR SWITCH ASSY
HINT:
All the regulator switches (front passenger's, rear left, rear right) should be inspected in the same procedure,
- Inspect the regulator switch continuity.
Standard:
If the result is not as specified, replace the regulator switch.
- Inspect the regulator switch continuity.
- INSPECT POWER WINDOW REGULATOR MOTOR
- Inspect the regulator motor operation.
HINT:
- Driver's side and rear RH regulator motors should be inspected in the same procedure.
- Passenger's side and rear LH regulator motors should be inspected in the same procedure.
- Check that the motor operates smoothly when the battery positive voltage is applied to each terminal of the connector.
Standard [Driver's side and rear RH side]:
STANDARDMeasuring condition Operational direction Battery positive (+) Terminal - 4 Clockwise toward driving axis Battery negative (-) Terminal - 5 Clockwise toward driving axis Battery positive (+) Terminal - 5 Counterclockwise toward driving axis Battery negative (-) Terminal - 4 Counterclockwise toward driving axis Standard [Front passenger's side and rear LH side]:
FRONT PASSENGER SIDE AND REAR LH SIDEMeasuring condition Operational direction Battery positive (+) Terminal - 5 Clockwise toward driving axis Battery negative (-) Terminal - 4 Clockwise toward driving axis Battery positive (+) Terminal - 4 Counterclockwise toward driving axis Battery negative (-) Terminal - 5 Counterclockwise toward driving axis If the result is not as specified, replace the motor.
- Inspect the PTC operation inside the regulator motor.NOTE: The inspection should be performed with the power window regulator and door glass installed to the vehicle.
- Set a DC 400 A probe of the TOYOTA electrical tester in the wire harness of terminal 4 or 5.NOTE: Match the arrow mark of the probe with the current direction.
- Set the door glass in the fully closed position.
- When 60 seconds have elapsed after the door glass is fully closed, check how long it takes for the current to change from approximately 16 - 34 A into 1 A or less when the power window switch is turned UP once again.
Standard: Approximately 4 - 90 seconds
- When approximately 60 seconds have elapsed after the inspection of the current cut-off, check that the door glass goes down when the power window regulator switch is turned DOWN.
If the result is not as specified, replace the motor.
- Set a DC 400 A probe of the TOYOTA electrical tester in the wire harness of terminal 4 or 5.
- Inspect the regulator motor operation.
- INSPECT RELAY (Making: P/W)
- Remove the power window relay from the instrument panel J/B.
- Inspect the power window relay.
POWER WINDOW RELAYCondition Terminal No. Specified condition Constant 1 <--> 2 Continuity Apply B+ between Terminals 1 and 2 3 <--> 5 Continuity If the result is not as specified, replace the relay.