Home >> Toyota >> 2003 >> ECHO 2D Sedan, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Self Diagnostics >> Diagnostic Tests >> DTC P0116: Engine Coolant Temperature Circuit Range/Performance Problem & DTC P0125: Insufficient Coolant Temperature For Closed Loop Fuel Control >> Circuit Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Circuit Description

For circuit description, see DTC P0115, DTC P0117 & DTC P0118 .

Detecting conditions of DTC P0116 are:

Detecting conditions of DTC P0125 are:

  1. If THW is less than 20°F (-6.7°C) or THA is less than 20°F (-6.7°C) 20 minutes or more after starting engine, engine coolant temperature sensor value is 68°F (20°C) or less (2 trip detection logic).
  2. If THW is greater than or equal to 20°F (-6.7°C) and THA is greater than or equal to 20°F (-6.7°C) and 50°F (10°C) at engine start, 5 minutes or more after starting engine, engine coolant temperature sensor value is 48°F (20°C) or less (2 trip detection logic).
  3. If THW is greater than or equal to 50°F (10°C) and THA is greater than or equal to 50°F (10°C) at engine start, 2 minutes or more after starting engine, engine coolant temperature sensor value is 48°F (20°C) or less (2 trip detection logic).