Service Data
CHARGING SERVICE DATA
| Battery | Specific gravity at 20°C (68°F) | 1.25 - 1.29 |
| Voltage at 20°C (68°F) | 12.5 - 12.9 V | |
| Generator | Rated output | 12V 130A |
| Rotor coil resistance at 20°C (68°F) | 2.3 - 2.7 ohm | |
| Slip ring diameter STD | 14.2 - 14.4 mm (0.559 - 0.567 in.) | |
| Minimum | 14.0 mm (0.551 in.) | |
| Brush exposed length STD | 10.5 mm (0.413 in.) | |
| Minimum | 4.5 mm (0.177 in.) | |
| Charging circuit | Without load STD amperage | 10 A or less |
| STD voltage | 13.2 - 14.8 V | |
| With load STD amperage | 30 A or less | |