Starter Rated voltage & output power 12 V 2.0 kW
Starter No-load characteristics - Current 100 A or less at 11.5 V
Starter No-load characteristics - rpm 2,500 rpm or less
Starter Brush length - STD 15.0 mm (0.591 in.)
Starter Brush length - Minimum 9.0 mm (0.354 in.)
Starter Spring installed load - STD 21.5 - 27.5 N (2.2 - 2.8 kgf, 4.8 - 6.2 lbf)
Starter Spring installed load - Minimum 12.7 N (1.3 kgf, 2.9 lbf)
Starter Commutator Diameter - STD 35.0 mm (1.378 in.)
Starter Commutator Diameter - Minimum 34.0 mm (1.339 in.)
Starter Commutator Undercut depth - STD 0.7 mm (0.028 in.)
Starter Commutator Undercut depth: Minimum 0.2 mm (0.008 in.)
Starter Commutator Circle runout Maximum 0.05 mm (0.0020 in.)
Starter Field frame Shunt coil resistance - at 20°C (68°F) 1.5 - 1.9 ohm