Inspection Procedure
- INSPECT DLC3 TERMINAL VOLTAGE (TC TERMINAL)
- Turn the ignition switch to ON.
- Measure voltage between terminals TC and CG of DLC3.
OK :
Voltage: 10-14 V
- OK: Go to 3
- NG: go next step
- CHECK HARNESS AND CONNECTOR (DLC3 - BODY GROUND)
- Check for open and short circuit in harness and connector between terminal CG of the DLC3 and body ground (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE ).
- NG: Repair Or Replace Harness Or Connector
- OK: go to next step
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - DLC3)
- Check for open and short circuit in harness and connector between terminal TC of the skid control ECU and DLC3 (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE ).
- NG: Repair Or Replace Harness Or Connector
- OK: Check And Replace Brake Actuator Assy (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE )