Possible Causes
DTC is set when ECM detects an open or short in mass air flow meter circuit for more than 3 seconds at an engine speed of 4000 RPM or less. If DTC P0100 exists, ECM will operate in fail-safe mode in which ignition timing is fixed at 5 degrees BTDC. Possible causes are:
- MAF meter circuit is open or shorted.
- Defective MAF meter.
- Defective ECM.