LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2003 >> Tundra Base, Standard >> Repair and Diagnosis >> General Information >> Specifications Index >> Common Specs & Procedures >> Charging System >> Generator >> Service Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Specifications

GENERATOR SERVICE SPECIFICATIONS

Application Specification
3.4L V6 - 80 Amp Generator Assembly
Rotor Coil resistance @ 68°F (20°C) 2.1-2.5 Ohms
Slip Ring Diameter
Standard .559-.567 in, (14.2-14.4 mm)
Minimum .504 in. (12.8 mm)
Brush Exposed Length
Standard .374-.453 in. (9.5-11.5 mm)
Minimum .059 in. (1.5 mm)
4.7L V8 - 100 Amp Generator Assembly
Rotor Coil resistance @ 68°F (20°C) 2.1-2.5 Ohms
Slip Ring Diameter
Standard .559-.567 in. (14.2-14.4 mm)
Minimum .504 in. (12.8 mm)
Brush Exposed Length
Standard .413 in. (10.5 mm)
Minimum .059 in. (1.5 mm)
GENERATOR REGULATED OUTPUT SPECIFICATIONS (1)

Application Amps Volts
Tundra 10 Or Less 13.2-14.8
(1) Specification given is with engine speed at 2000 RPM.