Emission Control Service Data: 2UZ-FE
Service Data Specifications Table (2UZ-FE)
| VSV for charcoal canister | ||
| Resistance | at 20°C (68°F) | 25 - 30 Ω |
| at 100°C (212°F) | 32 - 42 Ω | |
| VSV for EVAP | ||
| Resistance | at 20°C (68°F) | 26 - 30 Ω |
| Heated oxygen sensor | ||
| Resistance | 1 (HT) - 2 (+B) | 11 - 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity |
| Heated oxygen sensor No. 2 (Bank 1) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 - 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity |
| Heated oxygen sensor No. 2 (Bank 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 - 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity |
| Vapor pressure sensor | ||
| Power source voltage | VC - E2 | 4.5 - 5.5 V |
| Power output voltage | PTNK - E2 | 3.0 - 3.6 V |