Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0100: MAF sensor range check |
| Required sensors / components (Main) | MAF sensor |
| Required sensors / components (Related) | CKP sensor |
| Frequency of operation | Continuous |
| Duration | 3 sec |
| MIL Operation | Immediate: Engine RPM is less than 4,000 rpm 2 driving cycles: Engine RPM is 4,000 rpm or more |
| Sequence operation | None |