Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0136: HO2S Voltage |
| Related DTCs | P0136: HO2S Low Voltage |
| Required sensors / components (Main) | HO2S (Heated Oxygen Sensor) |
| Required sensors / components (Related) | ECT sensor, MAF sensor, VSS |
| Frequency of operation | Once per drive cycle |
| Duration | 480 sec: HO2S Voltage 300 sec: HO2S Low Voltage |
| MIL Operation | 2 driving cycles |
| Sequence operation | None |