Service Data
2AZ-FE:
2AZ-FE Service Data Specifications
| VSV for CCV | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 40 Ω | |
| VSV for EVAP | ||
| Resistance | 1 - 2 | 26 to 30 Ω at 20°C (68°F) |
| 1 - Body ground | 10 kΩ or higher | |
| 2 - Body ground | 10 kΩ or higher | |
| Air fuel ratio sensor | ||
| Resistance | 1 (HT) - 2 (+B) | 0.8 to 1.4 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 1.8 to 3.2 Ω at 800°C (1,472°F) | |
| Heated oxygen sensor (Bank 1 Sensor 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 a at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 23 to 32 fiat 800°C (1,472°F) | |
1MZ-FE/3MZ-FE:
1MZ-FE/3MZ-FE Service Data Specifications
| VSV for CCV | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 40 Ω | |
| VSV for EVAP | ||
| Resistance | 1 - 2 | 26 to 30 Ω at 20°C (68°F) |
| 1 - Body ground | 10 kΩ or higher | |
| 2 - Body ground | 10 kΩ or higher | |
| Air fuel ratio sensor | ||
| Resistance | 1 (HT) - 2 (+B) | 0.8 to 1.4 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 1.8 to 3.2 Ω at 800°C (1,472°F) | |
| Heated oxygen sensor (Bank 1 Sensor 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 23 to 32 flat 800°C (1,472°F) | |
| Heated oxygen sensor (Bank 2 Sensor 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 23 to 32 Ω at 800°C (1,472°F) | |