LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2004 >> Land Cruiser >> Repair and Diagnosis >> Electrical >> Starter >> Starting System (Specifications) >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

Service Data - Starting

Starter Rated voltage and output power   12 V 2.0 kW
No-load characteristics Current 100 A or less at 11.5V
  rpm 2,500 rpm or less
Brush length STD 15.0 mm (0.591 in.)
  Minimum 9.0 mm (0.354 in.)
Spring installed load STD 21.5 - 27.5 N (2.2 - 2.8 kgf, 4.8 - 6.2 lbf)
  Minimum 12.7 N (1.3 kgf, 2.9 lbf)
Commutator    
Diameter STD   35.0 mm (1.378 in.)
  Minimum 34.0 mm (1.339 in.)
Undercut depth STD 0.7 mm (0.028 in.)
  Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Field frame    
Shunt coil resistance at 20°C(68°F) 1.5 - 1.9 Ω
Magnetic switch    
Contact plate for wear Maximum 0.9 mm (0.035 in.)