O2S Test Result
Rear O2S (Bank 1 Sensor 2 and Bank 2 sensor 2) voltage monitor
O2S HST RESULT
| TEST DATA | Description of TEST DATA | Conversion Factor | Unit | Standard Value of TEST LIMIT |
|---|---|---|---|---|
| MIN O2S V | The minimum voltage during O2S monitoring | N/A | V | Between 0 and 0.4 V |
| MAX O2S V | The maximum voltage during O2S monitoring | N/A | V | Between 0.5 and 1.275 V |
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 sensor 2) crack monitor
O2S HST RESULT
| TEST DATA | Description of TEST DATA | Conversion Factor Unit | Standard Value of TEST LIMIT |
|---|---|---|---|
| Time $81 | Percentage in monitoring time where oxygen sensor voltage is less than 0.05 V | Multiply 0.3906 | Between 0 and 60 % |
| Time $84 | Percentage in monitoring time where oxygen sensor voltage is 0.70 V or more | Multiply 0.3906 | Between 20 and 100 % |
| Time $85 | Maximum Rich (gtequal 0.45 V) time | Multiply 0.2621 Second | Between 20 and 66.8 seconds |
If all the values ($81, $84 and $85) are out of the standard values, the ECM interprets this as a malfunction.