TID $01: CATALYST

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.0078 [No dimension] Catalyst deterioration level (Bank 1): Determined by waveforms of front HO2S (A/F sensor) and rear HO2S Malfunction criterion
0 $02 Multiply by 0.0078 [No dimension] Catalyst deterioration level (Bank 2): Determined by waveforms of front HO2S (A/F sensor) and rear HO2S Malfunction criterion
TID $02: EVAP

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.183 [mmHg] Test value of EVAP VSV stuck closed: Determined by fuel tank pressure change during vacuum introduction Malfunction criterion for EVAP VSV stuck closed
0 $02 Multiply by 0.0655 [Seconds] Test value of EVAP VSV stuck open: Determined by abnormal state continuation time Malfunction criterion for EVAP VSV stuck open
0 $03 Multiply by 0.0655 [Seconds] Test value of canister closed valve (CCV): Determined by abnormal state continuation time Malfunction criterion for CCV
0 $04 Multiply by 0.0458 [mmHg] Test value of 0.04 inch leak: Determined by fuel tank pressure change Malfunction criterion for 0.04 inch leak
0 $05 Multiply by 0.0458 [mmHg] Test value of 0.02 inch leak: Determined by fuel tank pressure change Malfunction criterion for 0.02 inch leak
TID $04: HO2S HEATER

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 1) Malfunction criterion
1 $02 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction criterion
1 $04 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 3) Malfunction criterion
1 $10 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 1) Malfunction criterion
1 $20 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 2) Malfunction criterion
1 $40 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 3) Malfunction criterion
TID $06: A/F SENSOR

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.000244 [No dimension Parameter that identifies A/F sensor response rate (Bank 1) Malfunction criterion
0 $11 Multiply by 0.000244 [No dimension Parameter that identifies A/F sensor response rate (Bank 2) Malfunction criterion
TID $07: A/F SENSOR HEATER

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.000076 or 0.00017 [A] Maximum heater current (Bank 1) 0.25 A
1 $10 Multiply by 0.000076 or 0.00017 [A] Maximum heater current (Bank 2) 0.25 A
TID $08: THERMOSTAT

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 [°C] ECT sensor output when estimated ECT reaches malfunction criterion Malfunction criterion