Typical Malfunction Thresholds
MALFUNCTION THRESHOLDS DETECTION
| Detection Criteria | Threshold | |
|---|---|---|
| P0110: | ||
| Intake air temperature sensor resistance (Intake air temperature) | Less than 98.5 Ω, or more than 156 kΩ (More than 140°C (284°F), or less than -40°C (-40°F) | |
| P0112: | ||
| Intake air temperature sensor resistance (Intake air temperature) | Less than 98.5 Ω (More than 140°C (284°F)) | |
| P0113: | ||
| Intake air temperature sensor resistance (Intake air temperature) | More than 156 kΩ(Less than -40°C (-40°F)) | |