2AZ-FE: 

EMISSION CONTROL SERVICE DATA (2AZ-FE)

VSV for CCV  
Resistance at 20°C (68°F) 25 to 30 Ω
Resistance at 100°C (212°F) 32 to 40 Ω
VSV for EVAP  
Resistance 1 - 2 26 to 30 ° at 20°C (68°F)
Resistance 1 - Body ground 10 kΩ or higher
Resistance 2 - Body ground 10 kΩ or higher
Air fuel ratio sensor  
Resistance 1 (HT) - 2 (+B) 0.8 to 1.4 ° at 20°C (68°F)
Resistance 1 (HT) - 2 (+B) 1.8 to 3.2 ° at 800°C (1,472°F)
Heated oxygen sensor (Bank 1 Sensor 2)  
Resistance 1 (HT) - 2 (+B) 11 to 16 ° at 20°C (68°F)
Resistance 1 (HT) - 2 (+B) 23 to 32 ° at 800°C (1,472°F)

1MZ-FE/3MZ-FE: 

EMISSION CONTROL SERVICE DATA (1MZ-FE/3MZ-FE)

VSV for CCV  
Resistance at 20°C (68°F) 25 to 30 Ω
Resistance at 100°C (212°F) 32 to 40 Ω
VSV for EVAP  
Resistance 1 - 2 26 to 30 ° at 20°C (68°F)
Resistance 1 - Body ground 10 kΩ or higher
Resistance 2 - Body ground 10 kΩ or higher
Air fuel ratio sensor  
Resistance 1 (HT) - 2 (+B) 0.8 to 1.4 ° at 20°C (68°F)
Resistance 1 (HT) - 2 (+B) 1.8 to 3.2 ° at 800°C (1,472°F)
Heated oxygen sensor (Bank 1 Sensor 2)  
Resistance 1 (HT) - 2 (+B) 11 to 16 ° at 20°C (68°F)
Resistance 1 (HT) - 2 (+B) 23 to 32 ° at 800°C (1,472°F)
Heated oxygen sensor (Bank 2 Sensor 2)  
Resistance 1 (HT) - 2 (+B) 11 to 16 ° at 20°C (68°F)
Resistance 1 (HT) - 2 (+B) 23 to 32 ° at 800°C (1,472°F)