Service Data
2AZ-FE:
EMISSION CONTROL SERVICE DATA (2AZ-FE)
| VSV for CCV | |
| Resistance at 20°C (68°F) | 25 to 30 Ω |
| Resistance at 100°C (212°F) | 32 to 40 Ω |
| VSV for EVAP | |
| Resistance 1 - 2 | 26 to 30 ° at 20°C (68°F) |
| Resistance 1 - Body ground | 10 kΩ or higher |
| Resistance 2 - Body ground | 10 kΩ or higher |
| Air fuel ratio sensor | |
| Resistance 1 (HT) - 2 (+B) | 0.8 to 1.4 ° at 20°C (68°F) |
| Resistance 1 (HT) - 2 (+B) | 1.8 to 3.2 ° at 800°C (1,472°F) |
| Heated oxygen sensor (Bank 1 Sensor 2) | |
| Resistance 1 (HT) - 2 (+B) | 11 to 16 ° at 20°C (68°F) |
| Resistance 1 (HT) - 2 (+B) | 23 to 32 ° at 800°C (1,472°F) |
1MZ-FE/3MZ-FE:
EMISSION CONTROL SERVICE DATA (1MZ-FE/3MZ-FE)
| VSV for CCV | |
| Resistance at 20°C (68°F) | 25 to 30 Ω |
| Resistance at 100°C (212°F) | 32 to 40 Ω |
| VSV for EVAP | |
| Resistance 1 - 2 | 26 to 30 ° at 20°C (68°F) |
| Resistance 1 - Body ground | 10 kΩ or higher |
| Resistance 2 - Body ground | 10 kΩ or higher |
| Air fuel ratio sensor | |
| Resistance 1 (HT) - 2 (+B) | 0.8 to 1.4 ° at 20°C (68°F) |
| Resistance 1 (HT) - 2 (+B) | 1.8 to 3.2 ° at 800°C (1,472°F) |
| Heated oxygen sensor (Bank 1 Sensor 2) | |
| Resistance 1 (HT) - 2 (+B) | 11 to 16 ° at 20°C (68°F) |
| Resistance 1 (HT) - 2 (+B) | 23 to 32 ° at 800°C (1,472°F) |
| Heated oxygen sensor (Bank 2 Sensor 2) | |
| Resistance 1 (HT) - 2 (+B) | 11 to 16 ° at 20°C (68°F) |
| Resistance 1 (HT) - 2 (+B) | 23 to 32 ° at 800°C (1,472°F) |