Monitor Strategy
TYPICAL ENABLING CONDITIONS
| Related DTCs | P0101: Mass air flow meter rationality |
| Required sensors/ components (Main) | Mass air flow meter |
| Required sensors/ components (Related) | Crankshaft position sensor, engine coolant temperature sensor and throttle position sensor |
| Frequency of operation | Continuous |
| Duration | 10 seconds |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |