O2S Test Result
O2S TEST RESULT TABLE
| Test ID | Test Items | Descriptions | Unit Conversions | Units | Standard Value |
|---|---|---|---|---|---|
| $07 | - | Minimum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | V | Less than maximum TEST LIMIT |
| $08 | - | Maximum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | V | More than minimum TEST LIMIT |
| $31 | - | Average time that HO2 sensor (sensor 1) output switches from Lean to Rich | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $32 | - | Average time that HO2 sensor (sensor 1) output switches from Rich to Lean | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $37 | - | Time until HO2 sensor voltage drops to 0.2 V during fuel-cut | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $81 | - | Percentage in monitor time while HO2 sensor (sensor 2) voltage is below 0.05 V | Multiply by 0.390 | % | Less than maximum TEST LIMIT |
| $84 | - | Percentage in monitor time while HO2 sensor (sensor 2) voltage is 0.7 V or more | Multiply by 0.390 | % | More than minimum TEST LIMIT |
| $85 | - | Continuous time that HO2 sensor (sensor 2) voltage is 0.45 V or more | Multiply by 0.26214 | Second | More than TEST LIMIT |
| $87 | - | Percentage in monitor time while HO2 sensor (sensor 2) voltage is 0.45 V or more | Multiply by 0.390 | % | More than TEST LIMIT |
Refer to PRE-CHECK for detailed information on O2S Test Result.