O2S Test Result (Mode 05 Data)
Refer to O2S TEST RESULT for detailed information on O2S Test Result.
O2S TEST RESULT (MODE 05 DATA)
| Test ID | Test Items | Descriptions | Unit Conversions | Units | Standard Values |
|---|---|---|---|---|---|
| $03 | - | Low sensor voltage for switch time calculation | Multiply by 0.005 | V | Same as TEST LIMIT |
| $04 | - | High sensor voltage for switch time calculation | Multiply by 0.005 | V | Same as TEST LIMIT |
| $31 | - | Average of lean to rich response time | Multiply by 0.04096 | Second | Between minimum and maximum TEST LIMIT |
| $32 | - | Average of rich to lean response time | Multiply by 0.04096 | Second | Between minimum and maximum TEST LIMIT |
| $38 | - | Average time per cycle of HO2 sensor voltage | Multiply by 0.04096 | Second | Between minimum and maximum TEST LIMIT. |