Mode 6 - 2005 TOYOTA: MR2
TID $04: HEATED OXYGEN SENSOR HEATER
| TLT | CID | Unit Conversions | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.000076 [A] | Maximum heated oxygen sensor heater current (Bank 1 Sensor 1) | Malfunction criteria for heated oxygen sensor heater |
| 1 | $02 | Multiply by 0.000076 [A] | Maximum heated oxygen sensor heater current (Bank 1 Sensor 2) | Malfunction criteria for heated oxygen sensor heater |
| 1 | $10 | Multiply by 0.000076 [A] | Maximum heated oxygen sensor heater current (Bank 2 Sensor 1) | Malfunction criteria for heated oxygen sensor heater |
TID $08: THERMOSTAT
| TLT | CID | Unit Conversions | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and minus 40 [°C] | Engine coolant temperature | Malfunction criteria for thermostat |
O2S TEST RESULT TABLE
| Test ID | Test Items | Descriptions | Unit Conversions | Units | Standard |
|---|---|---|---|---|---|
| $07 | MIN O2S V | Minimum HO2 sensor (bank 1, 2 sensor 1) voltage | Multiply by 0.005 | V | Less than maximum TEST LIMIT |
| $08 | MAX O2S V | Maximum HO2 sensor (bank 1, 2 sensor 1) voltage | Multiply by 0.005 | V | More than minimum TEST LIMIT |
O2S TEST RESULT TABLE
| Test ID | Test Items | Descriptions | Unit Conversions | Units | Standard Value |
|---|---|---|---|---|---|
| $38 | - | Average time per cycle of HO2 sensor voltage (bank 1 and 2) | Multiply by 0.04096 | second | Between minimum and maximum TEST LIMIT |
O2S TEST RESULT TABLE
| Test ID | Test Items | Descriptions | Unit Conversions | Units | Standard Value |
|---|---|---|---|---|---|
| $07 | - | Minimum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | V | Less than maximum TEST LIMIT |
| $08 | - | Maximum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | V | More than minimum TEST LIMIT |
| $31 | - | Average time that HO2 sensor (sensor 1) output switches from Lean to Rich | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $32 | - | Average time that HO2 sensor (sensor 1) output switches from Rich to Lean | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $37 | - | Time until HO2 sensor voltage drops to 0.2 V during fuel-cut | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $81 | - | Percentage in monitor time while HO2 sensor (sensor 2) voltage is below 0.05 V | Multiply by 0.390 | % | Less than maximum TEST LIMIT |
| $84 | - | Percentage in monitor time while HO2 sensor (sensor 2) voltage is 0.7 V or more | Multiply by 0.390 | % | More than minimum TEST LIMIT |
| $85 | - | Continuous time that HO2 sensor (sensor 2) voltage is 0.45 V or more | Multiply by 0.26214 | Second | More than TEST LIMIT |
| $87 | - | Percentage in monitor time while HO2 sensor (sensor 2) voltage is 0.45 V or more | Multiply by 0.390 | % | More than TEST LIMIT |
TID $01: CATALYST - SENSOR 1 HO2 SENSOR, SENSOR 2 HO2 SENSOR
| TLT | CID | Unit Conversions | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.0078 [No dimension] | Catalyst deterioration level: Determined by waveforms of HO2 sensor 1 and sensor 2 | Malfunction criteria for catalyst deterioration |
TID $02: EVAP SYSTEM - VACUUM MONITOR
| TLT | CID | Unit Conversions | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.0916 [mmHg] | Fuel tank pressure change during vacuum introduction | Malfunction criteria for EVAP VSV |
| 1 | $02 | Multiply by 0.0458 minus 2.93 [mmHg] | Fuel tank pressure change at switching over canister closed valve (CCV) and pressure switching valve (bypass VSV) | Malfunction criteria for CCV and bypass VSV |
| 0 | $03 | Multiply by 0.0458 [mmHg] | Fuel tank pressure change monitored by vapor pressure sensor | Malfunction criteria for 0.04 inch leak |
| 0 | $04 | Multiply by 0.0458 [mmHg] | Fuel tank pressure change monitored by vapor pressure sensor | Malfunction criteria for 0.02 inch leak |