A/F SENSOR HEATER

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$81 Maximum A/F sensor heater current Multiply by 0.173 A Malfunction thresholds
HO2S HEATER

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$81 Maximum rear HO2S heater current Multiply by 0.000076 A Malfunction thresholds
THERMOSTAT

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$81 ECT when estimated ECT reaches 75 °C (167 °F) Multiply by 0.625 and minus 40 °C 75°C or more
O2S TEST RESULT (REAR HO2S VOLTAGE)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$07 Minimum rear HO2S voltage N/A V Below 0.45 V
$08 Maximum rear HO2S voltage N/A V 0.6 V or more
$31 Time that rear HO2S output changes Lean to Rich N/A sec. Below 3 sec.
$32 Time that rear HO2S output changes Rich to Lean N/A sec. Below 3 sec.
O2S TEST RESULT (REAR HO2S SLOW RESPONSE)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$37 Time until rear HO2S voltage drops to below 0.2 V after fuel-cut starting N/A sec. Below 7 sec.
O2S TEST RESULT (REAR HO2S LOW VOLTAGE)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$81 Percentage in monitor time where rear HO2S voltage is below 0.05 V Multiply 0.3906 % Within 60%
$84 Percentage in monitor time where rear HO2S voltage is 0.7 V or more Multiply 0.3906 % 20% or more
$85 Continuous time that rear HO2S voltage is 0.45 V or more Multiply 0.2621 sec. 20 sec. or more
$87 Percentage in monitor time where rear HO2S voltage is 0.45 V or more Multiply 0.3906 % 40% or more
CATALYST

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$01 Ratio of rear HO2S (bank 1) locus length and criteria locus length of bank 1 catalyst Multiply by 0.0078 N/A 1 or less
MONITOR RESULT (EVAP VSV STUCK CLOSE)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$02/$81 FTP change "during negative pressure introduction"* Multiply by 0.09156 mmHg Malfunction thresholds
MONITOR RESULT (CCV STUCK CLOSE)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$02/$85 FTP change when CCV is commanded to open after EVAP leak check Multiply by 0.0458 minus 2.930 mmHg mmHg Malfunction thresholds
MONITOR RESULT (BYPASS VSV MALFUNCTION)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$02/$86 FTP change when bypass VSV is commanded to close after EVAP leak check Multiply by 0.0458 minus 2.930 mmHg mmHg Malfunction thresholds
MONITOR RESULT (EVAP LEAK (0.04 INCH) AND EVAP GROSS LEAK)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$02/$04 FTP increase after negative pressure introduction* Multiply by 0.0458 mmHg Malfunction thresholds
MONITOR RESULT (EVAP LEAK 0.02 INCH)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
$02/$05 FTP increase after "negative pressure introduction"* Multiply by 0.0458 mmHg Malfunction thresholds
EVAP SYSTEM CONDITION AND EVAP VSV CCV BYPASS VSV POSITION

EVAP System Condition EVAP VSV CCV Bypass VSV EVAP (FTP) Pressure
Before "negative pressure introduction" Closed (OFF) Open (OFF) Closed (OFF) Positive
During "negative pressure introduction Open (ON) Closed (ON) Open (ON) Intake manifold pressure is being applied to EVAP system
After "negative pressure introduction" CCV testing Closed (OFF) Open (OFF) Open (ON) Negative
After "negative pressure introduction" Bypass VSV testing Closed (OFF) Open (OFF) Closed (OFF) Negative
A/F SENSOR

TEST ID Description of TEST DATA Conversion Factor Unit Description of TEST LIMIT
$06/$81 Response rate deterioration level Multiply by 0.000244 N/A Malfunction thresholds