Mode 6 - 2005 TOYOTA: RAV4
A/F SENSOR HEATER
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $81 | Maximum A/F sensor heater current | Multiply by 0.173 | A | Malfunction thresholds |
HO2S HEATER
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $81 | Maximum rear HO2S heater current | Multiply by 0.000076 | A | Malfunction thresholds |
THERMOSTAT
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $81 | ECT when estimated ECT reaches 75 °C (167 °F) | Multiply by 0.625 and minus 40 | °C | 75°C or more |
O2S TEST RESULT (REAR HO2S VOLTAGE)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $07 | Minimum rear HO2S voltage | N/A | V | Below 0.45 V |
| $08 | Maximum rear HO2S voltage | N/A | V | 0.6 V or more |
| $31 | Time that rear HO2S output changes Lean to Rich | N/A | sec. | Below 3 sec. |
| $32 | Time that rear HO2S output changes Rich to Lean | N/A | sec. | Below 3 sec. |
O2S TEST RESULT (REAR HO2S SLOW RESPONSE)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $37 | Time until rear HO2S voltage drops to below 0.2 V after fuel-cut starting | N/A | sec. | Below 7 sec. |
O2S TEST RESULT (REAR HO2S LOW VOLTAGE)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $81 | Percentage in monitor time where rear HO2S voltage is below 0.05 V | Multiply 0.3906 | % | Within 60% |
| $84 | Percentage in monitor time where rear HO2S voltage is 0.7 V or more | Multiply 0.3906 | % | 20% or more |
| $85 | Continuous time that rear HO2S voltage is 0.45 V or more | Multiply 0.2621 | sec. | 20 sec. or more |
| $87 | Percentage in monitor time where rear HO2S voltage is 0.45 V or more | Multiply 0.3906 | % | 40% or more |
CATALYST
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $01 | Ratio of rear HO2S (bank 1) locus length and criteria locus length of bank 1 catalyst | Multiply by 0.0078 | N/A | 1 or less |
MONITOR RESULT (EVAP VSV STUCK CLOSE)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $02/$81 | FTP change "during negative pressure introduction"* | Multiply by 0.09156 | mmHg | Malfunction thresholds |
MONITOR RESULT (CCV STUCK CLOSE)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $02/$85 | FTP change when CCV is commanded to open after EVAP leak check | Multiply by 0.0458 minus 2.930 mmHg | mmHg | Malfunction thresholds |
MONITOR RESULT (BYPASS VSV MALFUNCTION)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $02/$86 | FTP change when bypass VSV is commanded to close after EVAP leak check | Multiply by 0.0458 minus 2.930 mmHg | mmHg | Malfunction thresholds |
MONITOR RESULT (EVAP LEAK (0.04 INCH) AND EVAP GROSS LEAK)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $02/$04 | FTP increase after negative pressure introduction* | Multiply by 0.0458 | mmHg | Malfunction thresholds |
MONITOR RESULT (EVAP LEAK 0.02 INCH)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $02/$05 | FTP increase after "negative pressure introduction"* | Multiply by 0.0458 | mmHg | Malfunction thresholds |
EVAP SYSTEM CONDITION AND EVAP VSV CCV BYPASS VSV POSITION
| EVAP System Condition | EVAP VSV | CCV | Bypass VSV | EVAP (FTP) Pressure |
|---|---|---|---|---|
| Before "negative pressure introduction" | Closed (OFF) | Open (OFF) | Closed (OFF) | Positive |
| During "negative pressure introduction | Open (ON) | Closed (ON) | Open (ON) | Intake manifold pressure is being applied to EVAP system |
| After "negative pressure introduction" CCV testing | Closed (OFF) | Open (OFF) | Open (ON) | Negative |
| After "negative pressure introduction" Bypass VSV testing | Closed (OFF) | Open (OFF) | Closed (OFF) | Negative |
A/F SENSOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Description of TEST LIMIT |
|---|---|---|---|---|
| $06/$81 | Response rate deterioration level | Multiply by 0.000244 | N/A | Malfunction thresholds |