Monitor Strategy
MONITOR STRATEGY (DTC P0325/0327/0328)
| Related DTCs | P0325: Knock sensor range check (Fluctuating) P0327: Knock sensor range check (Low voltage) P0328: Knock sensor range check (High voltage) |
|---|---|
| Required Sensors/Components (Main) | Knock sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 1 second |
| MIL Operation | Immediate |
| Sequence of Operation | None |