LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2005 >> Prius >> Repair and Diagnosis (Single Page) >> General Information >> OEM General Information >> Service Specifications >> Hybrid Control System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

Service Data - Hybrid Control System (1 Of 2)

Inverter Power switch ON (IG)  
Standard A2 (GIVA) - A16 (GINV) Approximately 0 V
  A3 (GIVB) - A16 (GINV) Approximately 0 V
  A4 (GUU) - A16 (GINV) Approximately 14 to 16 V
  A5 (GVU) - A16 (GINV) Approximately 14 to 16 V
  A6 (GWU) - A16 (GINV) Approximately 14 to 16 V
  A7 (MIVA) - A16 (GINV) Approximately 0 V
  A8 (MIVB) - A16 (GINV) Approximately 0 V
  A9 (MUU) - A16 (GINV) Approximately 14 to 16 V
  A10 (MVU) - A16 (GINV) Approximately 14 to 16 V
  A11 (MWU) - A16 (GINV) Approximately 14 to 16 V
  A12 (VH) - A16 (GINV) Approximately 0.5 V
  A13 (CPWM) - A32 (GCNV) Approximately 0 V
  A14 (GSDN) - A32 (GCNV) Approximately 2 to 4.5 V
  A15 (VL) - A32 (GCNV) Approximately 0.5 V
  A16 (GINV) - C2 (GND) Approximately 0 V
  A18 (GIWA) - A16 (GINV) Approximately 0 V
  A19 (GIWB) - A16 (GINV) Approximately 0 V
  A20 (CT) - A16 (GINV) Approximately 0 V
  A21 (GIVT) - A16 (GINV) Approximately 2 to 4.5 V
  A22 (GFIV) - A16 (GINV) Approximately 5 to 8 V
  A23 (MIWA) - A16 (GINV) Approximately 0 V
  A24 (MIWB) - A16 (GINV) Approximately 0 V
  A25 (MSDN) - A16 (GINV) Approximately 0 V
  A26 (MIVT) - A16 (GINV) Approximately 2 to 4.5 V
  A27 (MFIV) - A16 (GINV) Approximately 5 to 8 V
  A28 (OVH) - A16 (GINV) Approximately 5 to 8 V
  A29 (CSDN) - A32 (GCNV) Approximately 0 V
  A30 (FCV) - A32 (GCNV) Approximately 13.5 to 16.5 V
  A31 (OVL) - A32 (GCNV) Approximately 13.5 to 16.5 V
  A32 (GCNV) -- C2 (GND) Approximately 0 V
  B1 (ILK) - body ground Below 1 Ω
  C1 (IGCT) -- C2 (GND) Approximately 8 to 16 V
  C2 (GND) - body ground Below 1 Ω
Converter    
Operation "READY" lamp Auxi Nary battery voltage
  ON 14V
  OFF 12V
Out put current   Approximately 80A or less
Speed sensor (resolver)    
Standard A1 (GCS) - A4 (GCSG) 12.6 to 16.8 Ω
  A2 (GSN) - A5 (GSNG) 12.6 to 16.8 Ω
  A3 (GRF) - A6 (GRFG) 7.65 to 10.2 Ω
  B1 (MRF) - B4 (MRFG) 7.65 to 10.2 Ω
  B2 (MSN) - B5 (MSNG) 12.6 to 16.8 Ω
  B3 (MCS) - B6 (MCSG) 12.6 to 16.8 Ω
Temperature sensor    
Standard C1 (MMT) - C4 (MMTG) 87.3 to 110.5 kΩ at 10°C (50°F)
    23.8 to 28.5 kΩ at 40°C (104°F)
  C3 (OMT) - C6 (OMTG) 87.3 to 110.5 kΩ at 10°C (50°F)
    23.8 to 28.5 kΩ at 40°C (104°F)
Service Data - Hybrid Control System (2 Of 2)

Integration relay (IGCT Relay)    
HEV fuse (20A)    
Standard   Below 1 Ω
IGCT relay    
Standard 7J-1 - 7J-4 10 kΩ or higher
    Below 1 Ω
    (Battery voltage is added between terminals 7J-2 and 7J-3)
  7J-1 - 7K-1 Below 1 Ω
    Below 1 Ω
    (Battery voltage is added between terminals 7J-2 and 7J-3)
  7J-2 - 7J-3 Below 1 Ω
  7J-4 - 7K-1 No continuity
Battery plug    
Standard   No continuity
  Install the service plug grip Continuity
System main relay No. 1    
Continuity    
Standard Positive terminal - Negative terminal 10 kΩ or higher
  A1 (CONT1) - Terminal 5 Below 1 Ω
    (Apply voltage between the positive and negative terminals)
  A2 (CONT2) - B1 (CONT2) Below 1 Ω
  A3 (CONT3) - C1 (CONT3) Below 1 Ω
  B1 (GND) - GND terminal Below 1 Ω
  C2 (GND) - GND terminal Below 1 Ω
Resistance    
Standard A1 (CONT1) - Terminal 5 70 to 160 Ω
System main relay No. 2 and 3    
Continuity    
Standard Positive terminal - Negative terminal 10 kΩ or higher
    Below 1 Ω
    (Apply voltage between the connector terminals)
Resistance    
Standard Connector terminals 20 to 50 Ω
Battery current sensor    
Standard Positive probe to terminal 1 (VIB) 3.5 to 4.5 kΩ
  Negative probe to terminal 2 (GIB)  
  Positive probe to terminal 2 (GIB) 5 to 7 kΩ
  Negative probe to terminal 1 (VIB)  
  Positive probe to terminal 1 (VIB) 3.5 to 4.5 kΩ
  Negative probe to terminal 3 (IB)  
  Positive probe to terminal 3 (IB) 5 to 7 kΩ
  Negative probe to terminal 1 (VIB)  
  2 (GIB) - 3 (IB) 0.2 kΩ or less
System main resistor    
Standard   18 to 22 Ω
Battery blower relay No. 1    
Standard 3 -- 5 10 kΩ or higher
    Below 1 Ω
    (When battery voltage is applied to terminals 1 and 2)