Service Data
SERVICE DATA - EMISSION CONTROL
| Air-fuel ratio sensor E5-23 (A1A+) - E5-28 (E1) | 3.0 to 3.6 V |
| Voltage E5-23 (A1A+) - E5-28 (E1) | 3.0 to 3.6 V |
| Voltage E5-22 (A1A-)-E5-28 (E1) | 2.7 to 3.3 V |
| Resistance 1 (HT)-2 (+B) | 1.8 to 3.9Ω at 20°C (68°F) |
| Resistance 2 (+B)-4 (AF-) | 10 kΩ or higher |
| Vapor pressure sensor 1-3 | 4.5 to 5.5 V |
| Voltage 1-3 | 4.5 to 5.5 V |
| Voltage 2-3 | 3.0 to 3.6 V |
| Vacuum switching valve assy No. 2 1-2 | 26 to 30 Ω at 20°C (68°F) |
| Resistance 1-2 | 26 to 30 Ω at 20°C (68°F) |
| Charcoal canister vacuum switching valve 1-2 | 36 to 42 Ω at 20°C (68°F) |
| Resistance 1-2 | 36 to 42 Ω at 20°C (68°F) |
| Trap w/ outlet valve canister assy 1 - 2 | 25 to 30 Ω at 20°C (68°F) |
| Resistance (VSV for CCV (canister closed valve)) 1 - 2 | 25 to 30 Ω at 20°C (68°F) |
| Resistance (VSV for CCV (canister closed valve)) 1 - 2 | 32 to 40 Ω at 100°C (212°F) |
| Heated oxygen sensor 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| Resistance 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| Resistance 1 (HT)-4 (E) | 10 kΩ or higher |