Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0116: ECT sensor stuck at Low ECT P0116: ECT sensor stuck at High ECT |
| Required sensors/components (Main) | ECT sensor |
| Required sensors/components (Related) | CKP sensor, IAT sensor, MAF meter |
| Frequency of operation | Continuous |
| Duration | 250 sec. or more |
| MIL operation | 2 driving cycles: ECT sensor stuck at Low ECT 6 driving cycles: ECT sensor stuck at High ECT |
| Sequence of operation | None |