Service Data

Cooling Service Data

Thermostat    
Valve opening temperature   80 to 84°C (176 to 183°F)
Valve lift at 95°C (205°F) 10 mm (0.394 in.) or more
Radiator cap sub-assy    
Standard opening pressure   83 to 113 kPa (0.85 to 1.15 kgf/cm2 , 12.1 to 16.4 psi)
Minimum opening pressure   69 kPa (0.7 kgf/cm2 ,10.0 psi)
Cooling fan    
Standard amperage No.1 10.6 to 16.6A
  No.2 5.6 to 11.6 A
Cooling fan relay    
Specified condition Between terminals 1 and 2 Continuity
  Between terminals 3 and 5 No continuity