Monitor Strategy
MONITOR STRATEGY TABLE
| Related DTCs | P0100: MAF Meter Range Check (Chattering) P0102: MAF Meter Range Check (Low voltage) P0103: MAF Meter Range Check (High voltage) |
| Required sensors/ components (Main) | MAF Meter |
| Required sensors/ components (Related) | Crankshaft position sensor |
| Frequency of operation | Continuous |
| Duration | 3 seconds |
| MIL operation | Immediate: Engine RPM is less than 4,000 rpm 2 driving cycles: Engine RPM is 4,000 rpm or more |
| Sequence operation | None |