LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2006 >> Camry Base, Standard >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> Emission Control System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

2AZ-FE: 

SERVICE DATA - 2AZ-FE

VSV for CCV    
Resistance at 20 °C (68 °F) 25 to 30 Ω
  at 100 °C (212 °F) 32 to 40 Ω
VSV for EVAP    
Resistance 1 - 2 26 to 30 Ω at 20 °C (68 °F)
1 - Body ground 10 kΩ or higher
2 - Body ground 10 kΩ or higher
Air fuel ratio sensor    
Resistance 1 (HT) - 2 (+B) 0.8 to 1.4 Ω at 20 °C (68 °F)
1 (HT) - 2 (+B) 1.8 to 3.2 Ω at 800 °C (1,472 °F)
Heated oxygen sensor (Bank 1 Sensor 2)    
Resistance 1 (HT) - 2 (+B) 11 to 16 Ω at 20 °C (68 °F)
1 (HT) - 2 (+B) 23 to 32 Ω at 800 °C (1,472 °F)

1MZ-FE/3MZ-FE: 

SERVICE DATA - 1MZ-FE/3MZ-FE

VSV for CCV    
Resistance at 20 °C (68 °F) 25 to 30 Ω
at 100 °C (212 °F) 32 to 40 Ω
VSV for EVAP    
Resistance 1 - 2 26 to 30 Ω at 20 °C (68 °F)
1 - Body ground 10 kΩ or higher
2 - Body ground 10 kΩ or higher
Air fuel ratio sensor    
Resistance 1 (HT) - 2 (+B) 0.8 to 1.4 Ω at 20 °C (68 °F)
1 (HT) - 2 (+B) 1.8 to 3.2 Ω at 800 °C (1,472 °F)
Heated oxygen sensor (Bank 1 Sensor 2)    
Resistance 1 (HT) - 2 (+B) 11 to 16 Ω at 20 °C (68 °F)
1 (HT) - 2 (+B) 23 to 32 Ω at 800 °C (1,472 °F)
Heated oxygen sensor (Bank 2 Sensor 2)    
Resistance 1 (HT) - 2 (+B) 11 to 16 Ω at 20 °C (68 °F)
1 (HT) - 2 (+B) 23 to 32 Ω at 800 °C (1,472 °F)