POWER STEERING FLUID  
Fluid level rise Maximum 5 mm (0.20 in.)
Fluid pressure at idle speed with valve closed 7,800 - 8,300 kPa (80 - 85 kgf/cm2 , 1,138 - 1,209 psi)
STEERING WHEEL  
Steering effort at idle speed (Reference) 6 N.m (60 kgf.cm, 53 in..lbf)
POWER STEERING VANE PUMP (2AZ-FE)  
Vane pump rotating torque 0.27 N.m (2.8 kgf.cm, 2.4 in..lbf) or less
Vane pump shaft and vane pump housing seal clearance STD 0.009 - 0.031 mm (0.00035 - 0.00122 in.)
Maximum 0.07 mm (0.0028 in.)
Vane plate height Minimum 7.7 mm (0.303 in.)
Vane plate thickness Minimum 1.408 mm (0.05543 in.)
Vane plate length Minimum 11.993 mm (0.47216 in.)
Vane plate and vane rotor groove clearance Maximum 0.03 mm (0.0012 in.)
Spring free length Minimum 35.8 mm (1.409 in.)
POWER STEERING VANE PUMP (1MZ-FE/3MZ-FE)  
Vane pump rotating torque 0.27 N.m (2.8 kgf.cm, 2.4 in..lbf) or less
Vane pump shaft and vane pump housing oil clearance STD 0.027 - 0.054 mm (0.00106 - 0.00213 in.)
Maximum 0.07 mm (0.0028 in.)
Vane plate height Minimum 8.7 mm (0.343 in.)
Vane plate thickness Minimum 1.4 mm (0.055 in.)
Vane plate length Minimum 14.991 mm (0.59020 in.)
Clearance between the rotor groove and plate Maximum 0.03 mm (0.0012 in.)
Spring free length Minimum 32.24 mm (1.2693 in.)
POWER STEERING GEAR  
Steering rack runout Maximum 0.3 mm (0.012 in.)
Total preload (Tie rod rotating torque) (Turning) 0.83 - 3.43 N.m (7.3 - 30.4 kgf.cm, 7.3 - 30.4 in..lbf)
Total preload (Control valve rotating torque) (Turning) 1.2 - 1.5 N.m (12.2 - 15.3 kgf.cm, 10.6 - 13.3 in..lbf)