LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2006 >> Matrix Base, 4WD >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2006 TOYOTA >> Land Cruiser
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Land Cruiser

HEATED OXYGEN SENSOR HEATER (BANK 1 SENSOR 2)

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$42 $90 Multiply by 0.001 (A) Maximum sensor heater current Minimum test limit Maximum test limit
HEATED OXYGEN SENSOR HEATER (BANK 2 SENSOR 2)

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$46 $90 Multiply by 0.001 (A) Maximum sensor heater current Minimum test limit Maximum test limit
THERMOSTAT

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$E1 $E8 Multiply by 01 [°C] ECT sensor output when estimated
ECT reaches to malfunction criteria
Malfunction criteria Maximum test limit
HO2S BANK 1 SENSOR 2

MID TID Scaling Description of Test value Minimum Test Limit Maximum Test Limit
$02 $07 Multiply by 0.001 [V] Minimum sensor voltage Minimum test limit Maximum test limit
$02 $08 Multiply by 0.001 [V] Maximum sensor voltage Minimum test limit Maximum test limit
$02 $8F Multiply by 0.001 [g] Maximum oxygen storage capacity 0 Maximum test limit
HO2S BANK 2 SENSOR 2

MID TID Scaling Description of Test value Minimum Test Limit Maximum Test Limit
$06 $07 Multiply by 0.001 [V] Minimum sensor voltage Minimum test limit Maximum test limit
$06 $08 Multiply by 0.001 [V] Maximum sensor voltage Minimum test limit Maximum test limit
$06 $8F Multiply by 0.001 [g] Maximum oxygen storage capacity 0 Maximum test limit
MISFIRE MONITOR - ALL CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A1 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A1 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 1 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A2 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A2 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 2 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A3 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A3 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 3 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A4 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A4 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 4 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A5 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A5 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 5 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A6 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A6 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 6 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A7 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A7 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 7 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A8 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A8 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
MISFIRE MONITOR - 8 CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A9 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65,535
$A9 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65,535
CATALYST BANK 1 - ACTIVE A/F CONTROL METHOD

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$21 $A9 Multiply by 0.0003 (no dimension) Oxygen storage capacity of catalyst Minimum test limit for catalyst Maximum test limit for catalyst
CATALYST BANK 2 - ACTIVE A/F CONTROL METHOD

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$22 $A9 Multiply by 0.0003 (no dimension) Oxygen storage capacity of catalyst Minimum test limit for catalyst Maximum test limit for catalyst
SECONDARY AIR SYSTEM

Monitor ID Test ID Scaling Unit Description
$71 $E1 Multiply by 0.01 g/sec. AIR amount for AIR insufficient
$71 $E2 Multiply by 0.01 kPa Averaged AIR pressure for AIR pump stuck ON
$71 $E3 Multiply by 0.01 kPa Averaged AIR pressure for AIR pump stuck OFF
$71 $E4 Multiply by 0.01 kPa AIR pressure pulse for AIR valve and AIR VSV stuck open
$71 $E5 Multiply by 0.01 kPa AIR pressure pulse for AIR valve and AIR VSV stuck close
$71 $E6 Multiply by 0.01 kPa AIR pressure difference for AIR valve
$71 $E7 Multiply by 0.01 kPa AIR pressure difference for AIR VSV bank 1
$71 $E8 Multiply by 0.01 kPa AIR pressure difference for AIR VSV bank 2
$71 $E9 Multiply by 0.01 kPa AIR pressure pulse for AIR VSV stuck open bank 1 and bank 2
A/F SENSOR

MID TID Scaling Description of Test Value Minimum Test Limit Maximum test Limit
$01 $91 Multiply by 0.003 [mA] Air-fuel ratio sensor current for bank 1 sensor 1 Malfunction criterion for low side rationality Malfunction criterion for high side rationality
AIR FUEL RATIO SENSOR BANK 1 SENSOR 1

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$05 $8E Multiply by 0.0003 (No dimension) Response rate deterioration level for A/F sensor Malfunction criterion FF
AIR FUEL RATIO SENSOR BANK 2 SENSOR 1

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$01 $8E Multiply by 0.0003 (No dimension) Response rate deterioration level for A/F sensor Malfunction criterion FF
EVAP

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$3D $C9 Multiply by 0.01 [kPa] Test value for small leak (P0456)
Refer to pressure D (1)
Minimum test limit for small leak Maximum test limit for small leak
$3D $CA Multiply by 0.01 [kPa] Test value for gross leak (P0455)
Refer to pressure E (1)
Minimum test limit for gross leak Maximum test limit for gross leak
$3D $CB Multiply by 0.01 [kPa] Test value for leak detection pump stuck OFF (P2401)
Refer to pressure A (1)
Minimum test limit for leak detection pump stuck OFF Maximum test limit for leak detection pump stuck OFF
$3D $CD Multiply by 0.01 [kPa] Test value for leak detection pump stuck ON (P2402)
Refer to pressure A (1)
Minimum test limit for leak detection pump stuck ON Maximum test limit for leak detection pump stuck ON
$3D $CE Multiply by 0.01 [kPa] Test value for vent valve stuck OFF (vent) (P2420)
Refer to pressure C (1)
Minimum test limit for vent valve stuck ON Maximum test limit for vent valve stuck ON
$3D $CF Multiply by 0.01 [kPa] Test value for vent valve stuck ON (P2419)
Refer to pressure A (1)
Minimum test limit for vent valve stuck OFF Maximum test limit for vent valve stuck OFF
$3D $D0 Multiply by 0.01 [kPa] Test value for reference orifice low flow (P043E)
Refer to pressure B (1)
Minimum test limit for reference orifice low flow Maximum test limit for reference orifice low flow
$3D $D1 Multiply by 0.01 [kPa] Test value for reference orifice high flow (P043F)
Refer to pressure A (1)
Minimum test limit for reference orifice high flow Maximum test limit for reference orifice high flow
$3D $D4 Multiply by 0.01 [kPa] Test value for purge VSV stuck closed (P0441)
Refer to pressure F (1)
Minimum test limit for purge VSV stuck closed Maximum test limit for purge VSV stuck closed
$3D $D5 Multiply by 0.01 [kPa] Test value for purge VSV stuck open (P0441)
Refer to pressure E (1)
Minimum test limit for purge VSV stuck open Maximum test limit for purge VSV stuck open
$3D $D7 Multiply by 0.01 [kPa] Test value for purge flow (P0441)
Refer to pressure G (1)
Minimum test limit for purge flow Maximum test limit for purge flow
(1) Pressures A to G are indicated in the following diagram.
Fig 1: Identifying Driving Pattern
G04435441Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002