HO2S BANK 1 SENSOR 2 AND BANK 2 SENSOR 2

Test ID Description Conversion Factor Unit Note
$07 Minimum O2S voltage Multiply by 0.005 V -
$08 Maximum O2S voltage Multiply by 0.005 V
$31 Switch time from lean to rich Multiply by 0.04 Seconds These values are not used for malfunction judgment.
$32 Switch time from rich to lean Multiply by 0.04 Seconds
$37 Switch time from rich to lean during fuel-cut Multiply by 0.04 Seconds
$39 Switch time from 0.35 V to 0.2 V during fuel-cut Multiply by 0.04 Seconds
$81 Percentage of monitoring time when O2S voltage less than 0.05 V Multiply by 0.3906 % -
$84 Percentage of monitoring time when O2S voltage more than 0.7 V Multiply by 0.3906 %
$85 Maximum rich time Multiply by 0.2621 Seconds
$87 Percentage of monitoring time when O2S voltage 0.45 V or more Multiply by 0.3906 %
CATALYST - A/F SENSOR TYPE

TID TLT CID Scaling Unit Description
$01 0 $01 Multiply by 0.0078 No dimension Catalyst deterioration level - Bank 1:
Determined by waveforms of A/F sensor and HO2S
$01 0 $02 Multiply by 0.0078 No dimension Catalyst deterioration level - Bank 2:
Determined by waveforms of A/F sensor and HO2S
EVAP - LEVII TYPE

TID TLT CID Scaling Unit Description
$02 1 $01 Multiply by 0.183 mmHg Test value of EVAP VSV stuck closed:
Determined by fuel tank pressure change during vacuum introduction
$02 0 $02 Multiply by 0.0655 Seconds Test value of EVAP VSV stuck open:
Determined by duration that fuel tank pressure is higher than criteria
$02 0 $03 Multiply by 0.0655 Seconds Test value of canister closed valve (CCV):
Determined by duration that fuel tank pressure is lower than criteria
$02 0 $04 Multiply by 0.0458 mmHg Test value of 0.04 inch leak:
Determined by fuel tank pressure change
$02 0 $05 Multiply by 0.0458 mmHg Test value of 0.02 inch leak:
Determined by fuel tank pressure change
HO2S HEATER

TID TLT CID Scaling Unit Description
$04 1 $02 Multiply by 0.000076 A Maximum HO2S heater current - Bank 1 Sensor 2
$04 1 $20 Multiply by 0.000076 A Maximum HO2S heater current - Bank 2 Sensor 2
A/F SENSOR - STANDARD TYPE

TID TLT CID Scaling Unit Description
$06 0 $01 Multiply by 0.000244 No dimension A/F sensor response rate - Bank 1
$06 0 $10 Multiply by 0.000244 No dimension A/F sensor response rate - Bank 2
A/F SENSOR - ACTIVE A/F CONTROL TYPE

TID TLT CID Scaling Unit Description
$06 1 $02 Multiply by 0.000039 A A/F sensor current - Bank 1
$06 0 $02 Multiply by 0.000039 A A/F sensor current - Bank 1
$06 1 $12 Multiply by 0.000039 A A/F sensor current - Bank 2
$06 0 $12 Multiply by 0.000039 A A/F sensor current - Bank 2
A/F SENSOR HEATER

TID TLT CID Scaling Unit Description
$07 1 $01 Multiply by 0.00017 A Maximum heater current - Bank 1
$07 1 $10 Multiply by 0.00017 A Maximum heater current - Bank 2
THERMOSTAT

TID TLT CID Scaling Unit Description
$08 1 $01 Multiply by 0.625 subtract 40 °C ECT sensor output when estimated ECT reaches malfunction criteria