Knock Sensor: Inspection
WARNING: This page is about a different variant/trim than selected.
- INSPECT KNOCK SENSOR
- Check the resistance.
- Using an ohmmeter, measure the resistance between the terminals.
Resistance
RESISTANCE SPECIFIED CONDITIONS
| Tester Connection |
Specified Condition |
| 1 (Ground) - 2 (Output) |
120 to 280 k at 20°C (68°F) |
If the result is not as specified, replace the knock sensor.