DTC Summary
DTC SUMMARY
| DTCs | Monitoring Items | Malfunction Detection Conditions | Trouble Areas | Detection Timings | Detection Logic | ||
|---|---|---|---|---|---|---|---|
| P2401 | Vacuum pump stuck OFF | Vacuum pump creates negative pressure through 0.02 inch orifice, and EVAP system pressure is measured to determine leak pressure standard. 0.02 inch leak pressure standard is measured at the start and end of the leak check. If system pressure is higher than - 1.06 kPa (-7.95 mmHg)(1), or lower than -4.85 kPa (-36.38 mmHg)(1), ECM determines that vacuum pump is stuck OFF. |
|
While ignition switch is OFF | 2 trip | ||
| P2402 | Vacuum pump stuck ON | Vacuum pump creates negative pressure through 0.02 inch orifice, and EVAP system pressure is measured to determine leak pressure standard. If system pressure is higher than - 1.06 kPa (-7.95 mmHg)(1), or lower than -4.85 kPa (-36.38 mmHg)(1), ECM determines that vacuum pump is stuck ON. |
|
While ignition switch is OFF | 2 trip | ||
|
|||||||
HINT:
The vacuum pump is built into the pump module.