Monitor Description
WARNING: This page is about a different variant/trim than selected.
The resistance of the Throttle Position (TP) sensor varies in accordance with the throttle valve opening angle. The ECM transmits a standardized reference voltage to the : VC terminal of the TP sensor and calculates the throttle valve opening angle based on the voltage received from the Signal: VTA terminal of the sensor. When the throttle valve is near the fully closed position, the output voltage of the TP sensor is low. When it is near the fully open position, the output voltage is high.
If the ECM detects that the output voltage of the TP sensor is outside the normal range, the ECM interprets this as a malfunction in the TP sensor and sets a DTC.