Battery Current Sensor: Inspection
- INSPECT BATTERY CURRENT SENSOR
- Inspect the resistance.
- Measure the resistance between terminals 1 (VIB) and 2 (GIB).
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONTester Connection Resistance Positive probe to terminal 1 (VIB)
Negative probe to terminal 2 (GIB)3.5 to 4.5 kΩ Positive probe to terminal 2 (GIB)
Negative probe to terminal 1 (VIB)5 to 7 kΩ If the results are not as specified, replace the battery current sensor.
- Measure the resistance between terminals 1 (VIB) and 3 (IB).
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONTester Connection Resistance Positive probe to terminal 1 (VIB)
Negative probe to terminal 3 (IB)3.5 to 4.5 kΩ Positive probe to terminal 1 (VIB)
Negative probe to terminal 3 (IB)5 to 7 kΩ If the results are not as specified, replace the battery current sensor.
- Measure the resistance between terminals 2 (GIB) and 3 (IB).
Standard resistance:
0.2 kΩ or less
NOTE: Even if the probes are changed around, the resistance will not vary.If the result is not as specified, replace the battery current sensor.
- Measure the resistance between terminals 1 (VIB) and 2 (GIB).
- Inspect the resistance.