LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2006 >> Sienna CE >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> 3MZ-FE Starting System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

3MZ-FE STARTING SERVICE DATA

Starter assembly Specified current 90 A or less at 11.5 V
Starter relay Specified condition 1 - 2 Continuity
Specified condition 3 - 5 No continuity
Applying battery voltage terminals 1 and 2 Continuity
Battery (Except maintenance-free battery) Standard specific gravity 1.25 to 1.29 at 20 °C (68 °F)
Voltage 12.6 to 12.8 V at 20 °C (68 °F)
Voltage regulator Regulating voltage 13.2 to 14.8 V
Standard amperage 10 A or less
Starter armature assembly Maximum circuit runout 0.05 mm (0.0020 in.)
Standard depth 3.3 mm (0.1299 in.)
Maximum depth 4.0 mm (0.1575 in.)
Starter commutator end frame assembly Standard brush length 9.0 mm (0.354 in.)
Minimum brush length 4.0 mm (0.158 in.)