Inspection Procedure
- INSPECT MULTI-DISPLAY
- Disconnect the multi-display connectors E25 and E8.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
MULTI-DISPLAY RESISTANCETester connection Condition Specified condition GND1 - Body ground Always Below 1 Ω GND2 - Body ground Always Below 1 Ω GND3 - Body ground Always Below 1 Ω GND4 - Body ground Always Below 1 Ω GND5 - Body ground Always Below 1 Ω SGD1 - Body ground Always Below 1 Ω SGD2 - Body ground Always Below 1 Ω SGND - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard voltage
MULTI-DISPLAY VOLTAGETester connection Condition Specified condition +B1 - GND1 Always 10 to 14 V ACC - GND1 Ignition SW on (ACC) 10 to 14 V IG - GND1 Ignition SW on (IG) 10 to 14 V
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE