Inspection Procedure
HINT:
Troubleshoot each trouble symptom in accordance with the table below.
TROUBLE SYMPTOM CHART
| MIL remains illuminated | Start inspection from step 1 |
| MIL not illuminated | Start inspection from step 3 |
- CHECK WHETHER MIL TURNS OFF
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch on (IG).
- Turn the tester on.
- Check whether any DTCs have been stored (See DTC CHECK / CLEAR ). Note them down if necessary.
- Clear the DTCs (See DTC CHECK / CLEAR ).
- Check if the MIL turns off.
OK:
MIL should turn off.
OK: REPAIR CIRCUIT INDICATED BY OUTPUT DTC
NG: Go to Next Step
- CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)
- Disconnect the ECM connector.
- Turn the ignition switch on (IG).
- Check that the MIL is not illuminated.
OK:
MIL is not illuminated.
- Reconnect the ECM connector.
OK: REPLACE ECM
NG: CHECK AND REPLACE HARNESS AND CONNECTOR (COMBINATION METER - ECM)
- CHECK THAT MIL IS ILLUMINATED
- Check if the MIL is illuminated when the ignition switch is turned on (IG).
OK:
MIL should be illuminated.
OK: SYSTEM OK
NG: Go to Next Step
- Check if the MIL is illuminated when the ignition switch is turned on (IG).
- INSPECT COMBINATION METER ASSEMBLY (MIL CIRCUIT)
- See HOW TO PROCEED WITH TROUBLESHOOTING of the combination meter troubleshooting procedure.
NG: REPAIR OR REPLACE BULB OR COMBINATION METER ASSEMBLY
OK: CHECK AND REPLACE HARNESS AND CONNECTOR (COMBINATION METER - ECM)