Service Data
2GR-FE
2GR-FE COOLING - SERVICE DATA
| Thermostat | ||
| Valve opening temperature | 80 to 84 °C (176 to 183 °F) | |
| Valve lift | at 95 °C (203 °F) | 10 mm (0.394 in.) or more |
| Radiator cap sub-assembly | ||
| Specified opening pressure | 69.0 to 112.8 kPa (0.70 to 1.15 kgf/cm2 , 10.0 to 16.4 psi) | |
| Cooling fan | ||
| Standard amperage | at 20 °C (68 °F) | 8.0 to 12.0 A |