Information / Freeze Frame Data
WARNING: This page is about a different variant/trim than selected.
- FREEZE FRAME DATA
HINT:
The hybrid vehicle control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred. To confirm the details of the hybrid control system, check the detailed information for the DTC information code in the data list (INF code).
- Connect the intelligent tester to the DLC3.
- Turn the power switch on (IG) and turn the intelligent tester on.
- Select the following menu items: DIAGNOSIS / OBD/MOBD / HV ECU / DTC INFO / CURRENT CODES.
- Select a DTC in order to display its freeze frame data.
- Check the freeze frame data of the DTC that has been detected.
- Check the freeze frame information recorded with the DTC.
FREEZE FRAME DATA:
FREEZE FRAME DATAIntelligent Tester Display Measurement Item / Range (Display) Suspected Vehicle Status When Malfunction Occurs FREEZE DTC (DTC with require freeze frame data storage) DTC corresponding to displayed freeze frame data - INFORMATION 1 to 5 (DETAIL INFORMATION 1 to 5) Information code - COOLANT TEMP (Engine coolant temperature) Engine coolant temperature / Min.: -40°C, Max.: 140°C Cold or warmed-up engine ENGINE REV (Engine revolution) Engine speed / Min.: 0 rpm, Max.: 16,383.75 rpm Engine speed VEHICLE SPD (Vehicle SPD) Vehicle speed / Min.: 0 km/h, Max.: 255 km/h Stopped, or driving (at low, medium, or high speeds) ENG RUN TIME (Engine run time) Elapsed time after engine start / Min.: 0 sec, Max.: 65535 sec. Elapsed time after engine start +B (+B) Auxiliary battery voltage / Min.: 0 V, Max.: 65.535 V Auxiliary battery condition ACCEL POS #1 (Accelerator pedal position #1) Accelerator pedal position sensor No. 1 / Min.: 0%, Max.: 100% Idling, accelerating, or decelerating ACCEL POS #2 (Accelerator pedal position #2) Accelerator pedal position sensor No. 2 / Min.: 0%, Max.: 100% Idling, accelerating, or decelerating AMBIENT TEMP (Ambient Temperature) Ambient air temperature / Min.:-40°C, Max.: 215°C Hot or cold weather INTAKE AIR TEMP (Intake air temperature) Intake air temperature / Min.: -40°C, Max.: 140°C Hot or cold weather DTC CLEAR WARM (DTC Clear Warm Up Times) The number of times engine is warmed up after clearing DTCs / Min.: 0, Max.: 255 Frequency of malfunction recurrence after clearing DTCs DTC CLEAR RUN (DTC Clear Run Distance) Drive distance after clearing DTCs / Min.: 0 km, Max.: 65535 km Frequency of malfunction recurrence after clearing DTCs DTC CLEAR MIN {DTC Clear Min) Elapsed time after clearing DTCs / Min.: 0 min, Max.: 65535 min Elapsed time after clearing DTCs CALC LOAD (Calculate Load) Calculate load / Min.: 0%, Max.: 100% - THROTTLE POS (Throttle POS) Throttle position sensor / Min.: 0%, Max.: 100% Idling, accelerating, or decelerating ECU TYPE (Type pf ECU) ECU type Identifying ECU type: HV ECU BATTERY SOC (Battery State of Charge) Battery state of charge / Min.: 0%, Max.: 100% State of charge of HV battery DELTA SOC (Delta SOC) Difference between maximum and minimum value of SOC / Min.: 0%, Max.: 100% SOC variance IB BATTERY (Current value of Battery Pack) Current value of battery pack / Min.: -327.68 A, Max.: 327.67 A HV battery charge/discharge status - Amount of current during discharge is displayed with positive values
- Amount of current during charge is displayed with negative values
BATT INSIDE AIR (Inhalation-of-air temperature into a battery pack) Battery cooling fan intake air temperature Min.: -327.68°C, Max.: 327.67°C - VMF FAN VOLT1 (VMF fan motor voltage1) VMF fan voltage / Min.: -25.6 V, Max.: 25.4 V Cooling fan operation condition AUX. BAT V (Auxiliary battery voltage) Auxiliary battery voltage / Min.:-25.6 V, Max.: 25.4 V Auxiliary battery voltage WIN (Charge control value) Charge control power value / Min.: -64 kW, Max.: 63.5 kW Charge amount of HV battery WOUT (Discharge control value) Discharge control power value / Min.: -64 kW, Max.: 63.5 kW Discharge amount of HV battery COOLING FAN 1 (COOLING FAN MODE1) Cooling fan mode / Min.: 0, Max.: 40 HV battery cooling fan activation condition - Stopped: 0
- Low speed drive - high speed drive: 1-40
ECU CTRL MODE (ECU control mode) ECU control mode / Min.: 1, Max.: 5 HV battery control status SBLW RQST (Cooling fan stop control request (Standby Blower)) Standby blower request - BATT TEMP 1 to 4 (Temperature of battery TB 1 to 4) Battery temperature / Min.: -327.68°C, Max.: 327.67°C HV battery temperature V1 to V17 BATT BLOCK (Battery Block Voltage V01 to V17) Battery block voltage / Min.: -327.68 V, Max.: 327.67 V Each HV battery block voltage variance
- INFORMATION
HINT:
Similar to freeze frame data, the hybrid vehicle control ECU also records vehicle and driving condition information as INFORMATION (INF code) at the moment a DTC is stored.
- Select the information item which has an INF code from among INFORMATION 1 to 5.
- Check the information for the DTC.
INFORMATION:
MEASUREMENT ITEM RANGE DISPLAYIntelligent Tester Display Measurement Item / Range (Display) Suspected Vehicle Status When Malfunction Occurs INFORMATION Ω (INFORMATION Ω) Information code Indication of system with malfunction MG1 REV (Generator (MG1) Revolution) Generator revolution / Min.: -16,384 rpm, Max.: 16,256 rpm Generator speed - Forward rotation appears as "+"
- Backward rotation appears as "-"
MG2 REV (Motor (MG2) Revolution) Motor revolution / Min.: -16,384 rpm, Max.: 16,256 rpm Motor speed (proportionate to vehicle speed) - Forward rotation appears as "+"
- Backward rotation appears as "-"
Moving direction of vehicle- Forward rotation appears as "+"
- Backward rotation appears as "-"
MG1 TORQ (Generator (MG1) Torq) Generator torque / Min.: -512 N*m, Max.: 508 N*m When generator rotation in "+" direction: - Torque appears as "+" while generator discharges
- Torque appears as "-" while generator charges
When generator rotation in "-" direction:- Torque appears as "-" while generator discharges
- Torque appears as "+" while generator charges
MG2 TORQ (Motor (MG2) Torq) Motor torque / Min.: -512 N*m, Max.: 508 N*m When motor rotation in "+" direction: - Torque appears as "+" while motor discharges
- Torque appears as "-" while motor charges
When motor rotation in "-" direction:- Torque appears as "-" while motor discharges
- Torque appears as "+" while motor charges
INVERT TEMP-MG1 (Inverter temperature (MG1)) Generator inverter temperature / Min.: -50°C, Max.: 205°C Generator inverter temperature INVERT TEMP-MG2 (Inverter temperature (MG2)) Generator inverter temperature / Min.: -50°C, Max.: 205°C Motor inverter temperature MG2 TEMP (No2) (Motor temperature MG2 (No2)) Generator inverter temperature / Min.: -50°C, Max.: 205°C Generator temperature MG2 TEMP(No1) (Motor temperature MG2 (No1) Generator inverter temperature / Min.: -50°C, Max.: 205°C Motor temperature POWER RQST (Request Power) Request engine power / Min.: 0 W, Max.: 255 W Engine power output requested to ECM ENGINE SPD (Engine SPD) Engine speed / Min.: 0 rpm, Max.: 16320 rpm Engine speed MCYL CTRL POWER (Master Cylinder Control Torq) Master cylinder control torque / Min.: -512 N*m, Max.: 508 N*m Brake force requested by driver SOC (SOC) Battery state of charge / Min.: 0%, Max.: 100% State of charge of HV battery WOUT CTRL POWER (Wout Control Power) Power value discharge control / Min.: 0W, Max.: 81600 W Discharge amount of HV battery WIN CTRL POWER (Win Control Power) Power value charge control / Min.: -40800 W, Max.: 0 W Charge amount of HV battery DRIVE CONDITION ID (Drive Condition ID) Drive condition ID - Engine stopped: 0 Engine about to be stopped: 1
- Engine about to be started: 2
- Engine operated or operating: 3
- Generating or loading movement: 4
- Revving in P position: 6
Engine operating condition PWR RESOURCE VB (Power Resource VB) HV battery voltage / Min.: 0 V, Max.: 510 V HV battery voltage PWR RESOURCE IB (Power Resource IB) HV battery charge/discharge status / Min.: -256 A, Max.: 254 A HV battery charge and discharge current - Amount of current during discharge is indicated with positive values
- Amount of current during charge is indicated with negative values
SHIFT POSITION (Shift sensor shift position) Shift position (P, R, N, D or B position) P: 0, R: 1, N: 2, D: 3, B: 4 Shift position ACCEL SENSOR M (Accel sensor main) Accelerator pedal position sensor main / Min.: 0%, Max.: 100% Idling, accelerating, or decelerating AUX. BATT V (Auxiliary Battery Voltage) Auxiliary battery voltage / Min.: 0V, Max.: 20 V Auxiliary battery voltage CONVERTER TEMP (Converter Temperature) Boost converter temperature / Min.: -50°C, Max.: 205°C Boost converter temperature VL (VL-Voltage before raising pressure) High voltage before it is boosted / Min.: 0 V, Max.: 510 V High voltage level before it is boosted VH (VH-Voltage after raising pressure) High voltage after it is boosted Min.: 0 V, Max.: 765 V High voltage level after it is boosted IG ON TIME (The time of Ignition ON) The time after power switch on (IG) / Min.: 0 min, Max.: 255 min Time elapsed with power switch on (IG) VEHICLE SPD-MAX (Vehicle Speed (Max)) Maximum vehicle speed / Min.: -256 km/h, Max.: 254 km/h Over-discharging of HV battery A/C COSMPT PWR (Air-con consumption power) A/C consumption power / Min.: 0 kW, Max.: 5 kW A/C load ENG STOP RQST (Engine Stop Request) Engine stop request / NO or YES Engine stop request IDLING REQUEST (Engine Idling Request) Engine idling request / NO or YES Idle stop request ENGINE FUEL CUT (Engine Fuel Cut) Engine fuel cut request / NO or YES Fuel cut request HV BATT CH RQST (Main Battery Charging Request) HV battery charging request HV battery charging request ENG WARM UP RQT (Engine Warming up Request) Engine warming up request / NO or YES Engine warm-up request STOP SW COND (Stop SW) Stop light switch ON condition / NO or YES Brake pedal depressed or released CRUISE CONTROL (Cruise Control) Cruise control active condition / NO or YES Operation under cruise control ON or OFF EXCLUSIVE INFO 1 to 7 (Exclusive Information 1 to 7) Exclusive information (in numerical data) Exclusive information linked to Information OCCURRENCE ORDR (Occurrence order) Occurrence sequence of information Occurrence sequence of information INVT TMP-MG1 IG (Inverter temperature (MG1) after IG-ON) Generator inverter temperature after power switch on (IG) / Min.: -50°C, Max.: 205°C Generator inverter temperature soon after power switch on (IG) INVT TMP-MG2 IG (Inverter temperature (MG2) after IG-ON) Motor inverter temperature after power switch on(IG)/ Min.: -50°C, Max.: 205°C Motor inverter temperature soon after power switch on (IG) MG2 TEMP IG (Motor temperature (MG2) after IG-ON)) Motor temperature after power switch on (IG) / Min.: -50°C, Max.: 205°C Motor temperature soon after power switch on (IG) CONVRTR TEMPIG (Converter Temperature after IG-ON) Boost converter temperature after power switch on (IG) / Min.: -50°C, Max.: 205°C Boost converter temperature soon after power switch on (IG) SOCIG (Status Of Charge after IG-ON)) Battery state of charge after power switch on (IG)/ Min.: 0%, Max.: 100% Battery state of charge soon after power switch on (IG) INVT TMP-MG1 MAX (Inverter temperature (MG1) MAX) Generator inverter maximum temperature / Min.: -50°C, Max.: 205°C Overheating state of Generator inverter INVT TMP-MG2 MAX (Inverter temperature (MG2) MAX) Motor inverter maximum temperature / Min.: -50°C, Max.: 205°C Overheating state of Motor inverter MG2 TEMP MAX (Motor temperature (MG2) MAX) Motor maximum temperature / Min.: -50°C, Max.: 205°C Overheating state of Motor CONVRTR TMP MAX (Converter Temperature MAX) Boost converter maximum temperature / Min.: -50°C, Max.: 205°C Overheating state of boost converter SOC MAX (Status Of Charge MAX) Maximum status of charge / Min.: 0%, Max.: 100% Over-charging of HV battery SOC MIN (Status Of Charge MIN) Minimum status of charge/ Min.: 0%, Max.: 100% Over-charging of HV battery HV COOLANT TEMP (HV Coolant Temperature) HV coolant temperature / Min.: -40°C, Max.: 140°C HV coolant temperature