Service Data
EMISSION CONTROL - SERVICE DATA
| Air-fuel ratio compensation system | Voltage | Standard | B2 - B22 (A1A+) - B3 -1(E1) | 3.3 V |
| B2-23 (A2A+) - B3 -1 (E1) | 3.3 V | |||
| B2-22 (A1A-) - B3 -(E1) | 2.9 V | |||
| B2-31 (A2A-) - B3 -(E1) | 2.9 V | |||
| Fuel cut off rpm | Cut off | 2, 500 rpm | ||
| Return | 1, 200 rpm | |||
| Lead detection pump | Voltage | Standard | A23 (VC) -A28(E2) | 4.5 to 5.5 V |
| E22 (PPMP) -A28(E2) | 1.425 to 4.150 V | |||
| vacuum Switching Valve | Resistance | Standard | 1 - Body | 10 MΩ or higher at 20°C (68°F) |
| 2 - Body | 10 MΩ or higher at 20°C (68°F) | |||
| Air fuel ratio sensor (Bank 1, Bank 2) | Resistance | Standard | 1 (HT) - 2 (+B) | 1.8 to 3.4 flat 20°C (68°F) |
| 1(HT)-4 (E1) | 10 kΩ or higher | |||
| Heated oxygen sensor No. 2 (Bank 1, Bank 2) | Resistance | Standard | 1 (HT) - 2 (+B) | 11 to 16 at 20°C (68°F) |
| 1 (HT) - 4 (E1) | 10 kΩ or higher | |||