Service Data
Pressure sensor for air injection system
PRESSURE SENSOR FOR AIR INJECTION SYSTEM (2006/01-)
| Tester Connection | Voltage |
|---|---|
| AIP - E2 | 1.0 to 2.2 V |
Vacuum switching valve for air injection system
VACUUM SWITCHING VALVE FOR AIR INJECTION SYSTEM (2006/01-)
| Tester Connection | Specified Condition |
|---|---|
| 1 - 2 | 26 to 30 Ω at 20°C (68°F) |
| 1 - Body ground | 10 MΩ or higher |
| 2 - Body ground | 10 MΩ or higher |
Purge VSV
PURGE VSV (2006/01-)
| Tester Connection | Specified Condition |
|---|---|
| 1 - 2 | 26 to 30 Ω at 20°C (68°F) |
| 1 - Body ground 2 - Body ground | 10 MΩ or higher |
Air fuel ratio sensor
AIR FUEL RATIO SENSOR (2006/01-)
| Tester Connection | Specified Condition |
|---|---|
| 1 (HT) - 2 (+B) | 1.8 to 3.4 Ω at 20°C (68°F) |
Heated oxygen sensor
HEATED OXYGEN SENSOR (2006/01-)
| Tester Connection | Specified Condition |
|---|---|