LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2007 >> Matrix Base, Automatic >> Repair and Diagnosis >> Engine Performance >> Engine Control System (1ZZ-FE) >> SFI System >> DTC P043E Evaporative Emission System Reference Orifice Clog Up; DTC P043F Evaporative Emission System Reference Orifice High Flow >> Typical Enabling Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Enabling Conditions

All: 

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not present None

Enable conditions of EVAP key-off monitor 

ENABLE CONDITIONS OF EVAP KEY-OFF MONITOR

Atmospheric pressure 70 to 110 kPa (525 to 825 mmHg) [absolute pressure]
Battery voltage 10.5 V or higher
Vehicle speed 2.5 mph (4 km/h) or less
Ignition switch OFF
Time after key off 15 hours
EVAP pressure sensor malfunction (P0450, P0452, P0453) Not detected
EVAP canister purge valve Not operated by scan tool
EVAP canister vent valve Not operated by scan tool
EVAP leak detection pump Not operated by scan tool
Both of the following conditions set before key off Conditions 1 and 2
1. Duration that vehicle has been driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)

EVAP Key-off monitor sequence 1 to 8 

  1. Atmospheric pressure measurement 
    ATMOSPHERIC PRESSURE MEASUREMENT

    Next sequence is run if the following condition is met: -
    Atmospheric pressure change for 10 seconds Within 0.3 kPa (2.25 mmHg) in 1 second
  2. Reference pressure measurement 
    REFERENCE PRESSURE MEASUREMENT

    Next sequence is run if the following conditions are set: -
    EVAP pressure just after reference pressure measurement start Within 0.3 kPa (2.25 mmHg) in 1 second
    Reference pressure -1 kPa (-7.5 mmHg) or lower
    Reference pressure Saturated within 60 seconds
  3. EVAP canister vent valve close stuck check 
    EVAP CANISTER VENT VALVE CLOSE STUCK CHECK

    Next sequence is run if the following condition is set: -
    EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more
  4. Vacuum introduction and EVAP leak check 
    VACUUM INTRODUCTION AND EVAP LEAK CHECK

    Next sequence is run if the following condition is set: -
    EVAP pressure Saturated within 12 minutes
  5. EVAP canister purge valve close stuck check 
    EVAP CANISTER PURGE VALVE CLOSE STUCK CHECK

    Next sequence is run if the following condition is set: -
    EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more
  6. Second reference pressure measurement 
    SECOND REFERENCE PRESSURE MEASUREMENT

    Next sequence run if all of following conditions set: Condition 1,2, 3 and 4
    1. EVAP pressure just after reference pressure -1 kPa-g (-7.5 mmHg-g) or less
    2. Reference pressure -4.85 to -1.057 kPa-g (-36.4 to -7.93 mmHg-g)
    3. Reference pressure Saturated within 60 seconds
    4. Reference pressure difference between first and second Less than 0.7 kPa-g (5.25 mmHg-g)
  7. Leak check 
    SECOND REFERENCE PRESSURE

    Next sequence run if following condition set: -
    EVAP pressure when vacuum introduction complete Second reference pressure or less
  8. Atmospheric pressure measurement 
    ATMOSPHERIC PRESSURE MEASUREMENT

    EVAP monitor complete if following condition set: -
    Atmospheric pressure difference between sequence 1 and 8 Within 0.3 kPa-g (2.25 mmHg-g)