LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2007 >> Matrix XR, Automatic >> Repair and Diagnosis >> Engine Performance >> Engine Control System (1ZZ-FE) >> SFI System >> DTC P2401 Evaporative Emission System Leak Detection Pump Control Circuit Low; DTC P2402 Evaporative Emission System Leak Detection Pump Control Circuit High >> Typical Enabling Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Enabling Conditions

All: 

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not present None

Enable conditions of EVAP key-off monitor 

ENABLE CONDITIONS OF EVAP KEY-OFF MONITOR

Atmospheric pressure 70 to 110 kPa (525 to 825 mmHg) [absolute pressure]
Battery voltage 10.5 V or more
Vehicle speed 2.5 mph (4 km/h) or less
Ignition switch OFF
Time after key off 5 hours
EVAP pressure sensor malfunction (P0450, P0452, P0453) Not detected
EVAP canister purge valve Not operated by scan tool
EVAP canister vent valve Not operated by scan tool
EVAP leak detection pump Not operated by scan tool
Both of the following conditions set before key off Conditions 1 and 2
1. Duration that vehicle has been driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)

EVAP key-off monitor sequence 1 to 8 

  1. Atmospheric pressure measurement 
    ATMOSPHERIC PRESSURE MEASUREMENT

    Next sequence is run if the following condition is met: -
    Atmospheric pressure change for 10 seconds Within 0.3 kPa (2.25 mmHg) in 1 second
  2. Reference pressure measurement 
    REFERENCE PRESSURE MEASUREMENT

    Next sequence is run if the following conditions are met: -
    EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or less
    Reference pressure -4.5 to -1 kPa (-33.75 to -7.5 mmHg)
    Reference pressure Saturated within 60 seconds
  3. EVAP canister vent valve close stuck check 
    EVAP CANISTER VENT VALVE CLOSE STUCK

    Next sequence is run if the following condition is met: -
    EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more
  4. Vacuum introduction and EVAP leak check 
    VACUUM INTRODUCTION AND EVAP LEAK

    Next sequence is run if the following condition is met: -
    EVAP pressure Saturated within 12 minutes
  5. EVAP canister purge valve close stuck check 
    EVAP CANISTER PURGE VALVE CLOSE STUCK

    Next sequence is run if the following condition is met: -
    EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more
  6. Second reference pressure measurement 
    SECOND REFERENCE PRESSURE MEASUREMENT

    Next sequence run if all of following conditions set: Condition 1,2, 3 and 4
    1. EVAP pressure just after reference pressure -1 kPa-g (-7.5 mmHg-g) or less
    2. Reference pressure -4.85 to -1.057 kPa-g (-36.4 to -7.93 mmHg-g)
    3. Reference pressure Saturated within 60 seconds
    4. Reference pressure difference between first and second Less than 0.7 kPa-g (5.25 mmHg-g)
  7. Leak check 
    REFERENCE PRESSURE

    Next sequence run if following condition is met: -
    EVAP pressure when vacuum introduction complete Second reference pressure or less
  8. Atmospheric pressure measurement 
    ATMOSPHERIC PRESSURE MEASUREMENT

    EVAP monitor complete if following condition is met: -
    Atmospheric pressure difference between sequence 1 and 8 Within 0.3 kPa-g (2.25 mmHg-g)