Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | None |
P2111 (Throttle actuator stuck open):
DIAGNOSTIC PROCEDURE
| All of following conditions met | - |
| system guard* | ON |
| Throttle actuator current | 2 A or more |
| Throttle actuator close duty ratio | 80 % or more |
P2112 (Throttle actuator stuck closed):
DIAGNOSTIC PROCEDURE
| All of following conditions met | - |
| System guard* | ON |
| Throttle actuator current | 2 A or more |
| Throttle actuator open duty-cycle | 80 % or more |
| * System guard set when following conditions met | - |
| Throttle actuator | ON |
| Throttle actuator duty calculation | Executing |
| Throttle position sensor | Fail determined |
| Throttle actuator current-cut operation | Not executing |
| Throttle actuator power supply | 4 V or more |
| Throttle actuator | Fail determined |