SERVICE DATA REFERENCE

Inverter A-2 (GIVA) - A-16 (GINV) HV Approximately 0 V
A-3 (GIVB) - A-16 (GINV) Approximately 0 V
A-4 (GUU) - A-16 (GINV) Approximately 14 to 16 V
A-5 (GVU) - A-16 (GINV) Approximately 14 to 16 V
A-6 (GWU) - A-16 (GINV) Approximately 14 to 16 V
A-7 (MIVA) - A-16 (GINV) Approximately 0 V
A-8 (MIVB) - A-16 (GINV) Approximately 0 V
A-9 (MUU) - A-16 (GINV) Approximately 14 to 16 V
A-10 (MVU) - A-16 (GINV) Approximately 14 to 16 V
A-11 (MWU) - A-16 (GINV) Approximately 14 to 16 V
A-12 (VH) - A-16 (GINV) Approximately 0.5 V
A-13 (CPWM) - A-32 (GCNV) Approximately 0 V
A-14 (GSDN) - A-32 (GCNV) Approximately 2 to 4.5 V
A-15 (VL) - A-32 (GCNV) Approximately 0.5 V
A-16 (GINV) - C-2 (GND) Approximately 0 V
A-18 (GIWA) - A-16 (GINV) Approximately 0 V
A-19 (GIWB) - A-16 (GINV) Approximately 0 V
A-20 (CT) - A-16 (GINV) Approximately 0 V
A-21 (GIVT) - A-16 (GINV) Approximately 2 to 4.5 V
A-22 (GFIV) - A-16 (GINV) Approximately 5 to 8 V
A-23 (MIWA) - A-16 (GINV) Approximately 0 V
A-24 (MIWB) - A-16 (GINV) Approximately 0 V
A-25 (MSDN) - A-16 (GINV) Approximately 0 V
A-26 (MIVT) - A-16 (GINV) Approximately 2 to 4.5 V
A-27 (MFIV) - A-16 (GINV) Approximately 5 to 8 V
A-28 (OVH) - A-16 (GINV) Approximately 5 to 8 V
A-29 (CSDN) - A-32 (GCNV) Approximately 0 V
A-30 (FCV) - A-32 (GCNV) Approximately 13.5 to 16.5 V
A-31 (OVL) - A-32 (GCNV) Approximately 13.5 to 16.5 V
A-32 (GCNV) - C-2 (GND) Approximately 0 V
B-1 (ILK) - Body ground
After installing the probe to the terminal, temporarily install the inverter cover. It does not have to be tightened with the bolts at this point.
Below 1 Ω
C-1 (IGCT) - C-2 (GND) Approximately 8 to 16 V
C-2 (GND) - Body ground Below 1 Ω
Converter operation Auxiliary battery voltage : READY light ON 14 V
Auxiliary battery voltage : READY light OFF 12 V
Output current : READY light ON Approximately 80 A or less
Water pump with motor Battery positive terminal to terminal 1 and the battery negative terminal to terminal 2 Water pump motor operates properly
IGCT relay 7J-1 - 7J-4 HV 10 kΩ or higher
7J-1 - 7K-4 Below 1 Ω
7J-2 - 7J-3 Below 1 Ω
7J-4 - 7K-1 10 kΩ or higher
7J-1 - 7J-4 : When battery voltage is applied to terminals 7J-2 and 7J-3 Below 1 Ω
7J-1 - 7K-1 : When battery voltage is applied to terminals 7J-2 and 7J-3 Below 1 Ω