Monitor Description
The ECM detects a malfunction in the coolant heat storage (CHS) system with the CHS tank outlet temperature signal, the position of the water valve and the engine running condition. In order to ensure the reliable malfunction detection, the ECM detects coolant passage clogging malfunction in two ways. Thus, when the following two detection conditions are met, the ECM determines that the coolant passage has clogged and sets a DTC.
- When starting the engine, a variation in the CHS tank outlet temperature and engine coolant temperature before and after preheating is below 2°C (3.6°F).