Typical Enabling Conditions
P2111:
TYPICAL ENABLING CONDITIONS - P2111
| The monitor will run whenever the following DTCs are not present | None |
| All of the following conditions are met | - |
| System guard* | ON |
| Throttle motor current | 2 A or more |
| Throttle motor duty to open | 80% or more |
| * System guard is ON when the following conditions are met | - |
| Throttle actuator | ON |
| Throttle actuator duty calculation | Executing |
| Throttle position sensor | Fail determined |
| Throttle actuator current-cut operation | Not executing |
| Throttle actuator power supply | 4 V or more |
| Throttle actuator | Fail determined |
P2112:
TYPICAL ENABLING CONDITIONS - P2112
| The monitor will run whenever the following DTCs are not present | None |
| All of the following conditions are met | - |
| System guard* | ON |
| Throttle motor current | 2 A or more |
| Throttle motor duty to close | 80% or more |
| * System guard is ON when the following conditions are met | - |
| Throttle actuator | ON |
| Throttle actuator duty calculation | Executing |
| Throttle position sensor | Fail determined |
| Throttle actuator current-cut operation | Not executing |
| Throttle actuator power supply | 4 V or more |
| Throttle actuator | Fail determined |