Service Data
SERVICE DATA REFERENCE
| Battery plug | Resistance between terminals | 10 kΩ or higher |
| Install the service grip: Resistance between terminals |
Below 1 Ω | |
| No. 1 system main relay | Positive terminal - Negative terminal | 10 kΩ or higher |
| A-2 (CONT2) - B-2 (CONT2) | Below 1 Ω | |
| A-3 (CONT3) - C-2 (CONT3) | Below 1 Ω | |
| B-1 (GND) - GND | Below 1 Ω | |
| C-1 (GND) - GND | Below 1 Ω | |
| Apply battery voltage between the GND terminal and CONT1 terminal of the connector A: Positive terminal - Negative terminal |
Below 1 Ω | |
| A-1 (CONT1) - GND | 70 to 160 kΩ | |
| No. 2 system main relay | Positive terminal - Negative terminal | 10 kΩ or higher |
| Apply battery voltage between the connector terminals: Positive terminal - Negative terminal |
Below 1 Ω | |
| Resistance between the connector terminals | 20 to 50 kΩ | |
| No. 3 system main relay | Positive terminal - Negative terminal | 10 kΩ or higher |
| Apply battery voltage between the connector terminals: Positive terminal - Negative terminal |
Below 1 Ω | |
| Resistance between the connector terminals | 20 to 50 kΩ | |
| System main resistor | Resistance between terminals | 18 to 22 Ω |
| Battery blower relay | 3 - 5 | 10 kΩ or higher |
| When battery voltage is applied to terminals 1 and 2: 3 - 5 |
Below 1 Ω | |
| Battery current sensor | Positive probe to terminal 1 (VIB) Negative probe to terminal 2 (GIB) | 3.5 to 4.5 kΩ |
| Positive probe to terminal 2 (GIB) Negative probe to terminal 1 (VIB) | 5 to 7 kΩ | |
| Positive probe to terminal 1 (VIB) Negative probe to terminal 3 (IB) A083579E02 | 3.5 to 4.5 kΩ | |
| Positive probe to terminal 1 (VIB) Negative probe to terminal 3 (IB) | 5 to 7 kΩ |